This training program focuses on developing and applying a laser microscopy technique to image pigmented lesions. The long-term objective is to fundamentally improve the detection and treatment of melanoma. Presently, melanoma is diagnosed from a pathologist's examination of a biopsy. While the criteria for evaluation were developed from the study of thick melanomas (with a typically fatal patient outcome), the majority of today's rising incidence of melanoma is accounted for by thin, early-stage lesions. Some pathologists question whether these criteria accurately predict a thin lesion's potential to develop into cancer. Furthermore, numerous studies have concluded that pathologists examining the same biopsy often disagree on the diagnosis of melanoma. Other studies have concluded that the rising incidence of melanoma can be explained by an 'epidemic' of overdiagnoses and costly false negatives. What is clear is that better methods are need for detecting melanoma and separating benign from malignant pigmented lesions. Therefore, there is a need for studies of early-stage melanoma, in order to look for biomarkers that reliably predict a suspicious lesion's malignant potential. This requires two things: a live model of early stage melanoma and an imaging method that is well suited for characterizing pigmented lesions. To this end, we propose in vivo imaging of an animal model (human skin, seeded with melanoma cell lines, grafted onto mice) with nonlinear pump-probe microscopy. Nonlinear pump-probe microscopy is a modality ideally suited for studying pigmented lesions. This method measures the microscopic distribution of the two types of melanin found in human skin, eumelanin and pheomelanin. The distribution of these pigments is of clinical importance: when compared with benign lesions, melanomas tend to contain more eumelanin and have a spatially heterogeneous pigment composition. This chemical contrast based on pump-probe spectroscopy of melanin reports on the metabolism and biologic behavior of melanocytes, the cells involved in melanoma. The pump-probe images are acquired noninvasively, without disrupting the skin under study, with considerably less optical intensity than is used in commercially available skin imaging systems based on multiphoton autofluorescence.
The specific aims are: 1) to improve contrast between melanocytes and keratinocytes; 2) to image the different progressive stages of early melanoma; and 3) to investigate the feasibility of extending pump-probe microscopy to a related condition, ocular melanoma.

Public Health Relevance

We propose to develop and apply a novel imaging technology for the study of early-stage melanoma. This technology, nonlinear pump-probe microscopy, generates images with contrast specific for diagnosing pigmented lesions, and has the potential to noninvasively detect early melanomas without excision and to reduce false negatives and false positives in histopathology. Reducing false negatives lowers cancer fatalities, while reducing false positives lowers overall healthcare costs.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Postdoctoral Individual National Research Service Award (F32)
Project #
5F32CA168497-03
Application #
8836497
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Mcguirl, Michele
Project Start
2013-04-03
Project End
2015-08-10
Budget Start
2015-04-03
Budget End
2015-08-10
Support Year
3
Fiscal Year
2015
Total Cost
Indirect Cost
Name
Duke University
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
044387793
City
Durham
State
NC
Country
United States
Zip Code
27705
Wilson, Jesse W; Robles, Francisco E; Deb, Sanghamitra et al. (2017) Comparison of pump-probe and hyperspectral imaging in unstained histology sections of pigmented lesions. Biomed Opt Express 8:3882-3890
Thompson, Andrew; Robles, Francisco E; Wilson, Jesse W et al. (2016) Dual-wavelength pump-probe microscopy analysis of melanin composition. Sci Rep 6:36871
Fischer, Martin C; Wilson, Jesse W; Robles, Francisco E et al. (2016) Invited Review Article: Pump-probe microscopy. Rev Sci Instrum 87:031101
Wilson, Jesse W; Park, Jong Kang; Warren, Warren S et al. (2015) Flexible digital signal processing architecture for narrowband and spread-spectrum lock-in detection in multiphoton microscopy and time-resolved spectroscopy. Rev Sci Instrum 86:033707
Wilson, Jesse W; Degan, Simone; Gainey, Christina S et al. (2015) Comparing in vivo pump-probe and multiphoton fluorescence microscopy of melanoma and pigmented lesions. J Biomed Opt 20:051012
Robles, Francisco E; Deb, Sanghamitra; Wilson, Jesse W et al. (2015) Pump-probe imaging of pigmented cutaneous melanoma primary lesions gives insight into metastatic potential. Biomed Opt Express 6:3631-45
Simpson, Mary Jane; Wilson, Jesse W; Robles, Francisco E et al. (2014) Near-infrared excited state dynamics of melanins: the effects of iron content, photo-damage, chemical oxidation, and aggregate size. J Phys Chem A 118:993-1003
Robles, Francisco E; Samineni, Prathyush; Wilson, Jesse W et al. (2013) Pump-probe nonlinear phase dispersion spectroscopy. Opt Express 21:9353-64
Simpson, Mary Jane; Glass, Keely E; Wilson, Jesse W et al. (2013) Pump-Probe Microscopic Imaging of Jurassic-Aged Eumelanin. J Phys Chem Lett 4:1924-1927
Wilson, Jesse W; Vajzovic, Lejla; Robles, Francisco E et al. (2013) Imaging microscopic pigment chemistry in conjunctival melanocytic lesions using pump-probe laser microscopy. Invest Ophthalmol Vis Sci 54:6867-76

Showing the most recent 10 out of 11 publications