This project aims to characterize the local changes in pancreatic islet inflammation (referred to as insulitis) and volume loss associated with type-1 diabetes (T1D) by developing novel computational image analysis algorithms that quantify such changes from magnetic resonance imaging (MRI) data. In the United States alone, as many as three million people may have T1D, with 80 new cases diagnosed every day, costing almost $15B annually (source: JDRF). Understanding the mechanisms of autoimmune destruction of cells at the organ level is important for developing new early diagnostic criteria and effective treatment strategies and preventative therapies. Clinical occultness of much of the autoimmune process, along with the difficult access to the location of the endocrine islets of Langerhans have slowed progress in understanding the etiology and progression of T1D. However, MRI alleviates this by permitting noninvasive, local measurement of pancreatic anatomy (such as the volume), in addition to insulitis via the use of magnetic nanoparticle (MNP) agents, making cross-sectional and longitudinal T1D imaging studies feasible. To that end, accurate correspondence among pancreatic regions of two or more images are required in order to compute 1) insulitis from pre/post- infusion MNP-MR images, 2) the progress of insulitis over time, and 3) the local change in pancreatic volume over time, in addition to 4) comparing all of these quantities across subjects. Such a point-wise correspondence is provided by image registration (alignment). This proposal aims to build on my background in brain image analysis and develop novel image registration (alignment) tools to accurately compute point- wise correspondence between pancreas images acquired from different subjects at different times, and subsequently use them in cross-sectional and longitudinal pancreatic imaging to develop new biomarkers, by locally tracking long-term inflammatory and volume changes in individuals with clinical and/or occult T1D. Specifically, we propose to develop an inherently-symmetric quasi-volume-preserving (QVP) non-rigid image registration algorithm for the pancreas, which, in contrast to the existing algorithms in the literature, avoids regional biases and the concomitant errors by defining a uniform objective function. Furthermore, the intergroup differences and intragroup variability are measured by constructing unbiased statistical pancreatic atlases of healthy and T1D cohorts, using a novel, improved group-wise registration algorithm. My long-term career goal is to establish and direct an inter-disciplinary research program at a top-notch academic institution, which will focus on developing creative approaches and innovative computational tools for processing biomedical images, in order to facilitate the investigation of the relationship between medical images and clinical data, and improve patient diagnosis and outcomes. My main objective for the K01 award period is to become an expert in T1D, in addition to abdominal - and especially pancreatic - MR acquisition and image analysis, and to advance this field by translating the skills I had previously acquired in brain image reconstruction and analysis. To achieve this goal, there are three important areas where I require additional training, mentoring, and experience: 1) diabetes, 2) abdominal imaging with contrast agents, and 3) advanced study design and biostatistics. I propose to acquire this training through direct mentoring, didactic coursework, modular courses, seminar series, and scientific meetings. The proposed project will form the foundation of my independent computational abdominal imaging research program, which will have diabetes at the core of its clinical focus.

Public Health Relevance

This proposal describes novel computational technology that is necessary for the exploration of the vast amount of information that exists in magnetic resonance images (MRI) of the pancreas, thereby enabling MRI to be used in cross-sectional and longitudinal type-1 diabetes (T1D) studies. The inflammation of the islets of Langerhans, resulting from autoimmune breakdown of cells in T1D, has been recently observed via MRI with magnetic-nanoparticle agents; however, the spatial quantification of the inflammation - and the pancreatic volume loss - requires exact computational tools, such as accurate pancreas-specific image alignment (registration) methods, which we propose to develop and subsequently apply in an existing cross-sectional and longitudinal T1D imaging investigation. The results will provide a more comprehensive understanding of the onset and the progression of T1D, along with a new pipeline to assess the effectiveness of the interventions.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Research Scientist Development Award - Research & Training (K01)
Project #
1K01DK101631-01A1
Application #
8966899
Study Section
Kidney, Urologic and Hematologic Diseases D Subcommittee (DDK)
Program Officer
Spain, Lisa M
Project Start
2015-07-15
Project End
2020-04-30
Budget Start
2015-07-15
Budget End
2016-04-30
Support Year
1
Fiscal Year
2015
Total Cost
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
Aganj, Iman (2018) Automatic Verification of the Gradient Table in Diffusion-Weighted MRI Based on Fiber Continuity. Sci Rep 8:16541
Aganj, Iman; Harisinghani, Mukesh G; Weissleder, Ralph et al. (2018) Unsupervised Medical Image Segmentation Based on the Local Center of Mass. Sci Rep 8:13012
Wang, Hui; Magnain, Caroline; Wang, Ruopeng et al. (2018) as-PSOCT: Volumetric microscopic imaging of human brain architecture and connectivity. Neuroimage 165:56-68
Zhang, Yingzhuo; Aganj, Iman; van der Kouwe, André J W et al. (2017) Accurate High-speed 3D-Registration of EPI vNavs for Head Motion Correction. Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson M 25:3944
Tong, Tong; Aganj, Iman; Ge, Tian et al. (2017) Functional density and edge maps: Characterizing functional architecture in individuals and improving cross-subject registration. Neuroimage 158:346-355
Aganj, Iman; Fischl, Bruce (2017) Multimodal Image Registration through Simultaneous Segmentation. IEEE Signal Process Lett 24:1661-1665
Aganj, Iman; Iglesias, Juan Eugenio; Reuter, Martin et al. (2017) Mid-space-independent deformable image registration. Neuroimage 152:158-170
Koley, Subhranil; Chakraborty, Chandan; Mainero, Caterina et al. (2016) A Fast Approach to Automatic Detection of Brain Lesions. Brainlesion (2016) 10154:52-61
Zhang, Yingzhuo; Aganj, Iman; van der Kouwe, André J W et al. (2016) Effects of Resolution and Registration Algorithm on the Accuracy of EPI vNavs for Real Time Head Motion Correction in MRI. Conf Comput Vis Pattern Recognit Workshops 2016:583-591