We have designed and constructed a preliminary 4T whole head volume array RF coil that works within our head gradient set. Previously, it has been demonstrated that substantial SNR gains are possible with a volume coil array consisting of shorter volume coils covering an extended FOV [38, 39] over a single coil covering the same FOV. We utilized this approach using a combination of two short quadrature birdcage coils to cover the whole human head. Applications such as single shot EPI which is routinely used in fMRI studies currently requires the use of the head gradient set in order to achieve sufficiently fast switching times at 4 T. Therefore, one of the requirements was to build such a coil within the confines of a head gradient set. The isolation between the quadrature ports of either coil was below -25 dB. This isolation was sufficient for imaging without further active preamplifier protection. The electromagnetic coupling between the coils could be adjusted to be below -18 dB at the feeding points. Load changes from subject to subject were found not to be critical in regard to coil decoupling. The necessary adjustments for tune and match from subject to subject was accomplished within minutes. Tune and match was easily adjusted for each birdcage coil separately thus also indicating minimal coil interactions. We obtained images to compare the SNR and homogeneity of the birdcage array coil with a high-pass birdcage coil. These images showed that when the subject was appropriately placed, Coil #1 covered the cerebellum, the brain stem and the lower part of the cerebral cortex and Coil #2 imaged the rest of brain. High sensitivity and homogeneity was observed in the combined images over the entire head and especially in the cerebral cortex, resulting in a maximal signal-to noise gain of up to 40% as compared with a 22 cm long high-pass birdcage even though the axially the FOV was substantially larger than then provided by the single high-pass birdcage. The axial homogeneity in the overlap area was excellent and comparable to that of a single birdcage coil.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR008079-10
Application #
6609279
Study Section
Project Start
2002-06-01
Project End
2003-05-31
Budget Start
Budget End
Support Year
10
Fiscal Year
2002
Total Cost
Indirect Cost
Name
University of Minnesota Twin Cities
Department
Type
DUNS #
168559177
City
Minneapolis
State
MN
Country
United States
Zip Code
55455
Herzberg, Max P; Hodel, Amanda S; Cowell, Raquel A et al. (2018) Risk taking, decision-making, and brain volume in youth adopted internationally from institutional care. Neuropsychologia 119:262-270
U?urbil, Kamil (2018) Imaging at ultrahigh magnetic fields: History, challenges, and solutions. Neuroimage 168:7-32
Foell, Jens; Palumbo, Isabella M; Yancey, James R et al. (2018) Biobehavioral threat sensitivity and amygdala volume: A twin neuroimaging study. Neuroimage 186:14-21
Magnitsky, Sergey; Pickup, Stephan; Garwood, Michael et al. (2018) Imaging of a high concentration of iron labeled cells with positive contrast in a rat knee. Magn Reson Med :
Lee, Byeong-Yeul; Zhu, Xiao-Hong; Woo, Myung Kyun et al. (2018) Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming. NMR Biomed 31:
Wilson, Sylia; Malone, Stephen M; Hunt, Ruskin H et al. (2018) Problematic alcohol use and hippocampal volume in a female sample: disentangling cause from consequence using a co-twin control study design. Psychol Med 48:1673-1684
Bolan, Patrick J; Kim, Eunhee; Herman, Benjamin A et al. (2017) MR spectroscopy of breast cancer for assessing early treatment response: Results from the ACRIN 6657 MRS trial. J Magn Reson Imaging 46:290-302
Nelson, Brent G; Bassett, Danielle S; Camchong, Jazmin et al. (2017) Comparison of large-scale human brain functional and anatomical networks in schizophrenia. Neuroimage Clin 15:439-448
Wang, Yi; Shao, Xingfeng; Martin, Thomas et al. (2016) Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction. Magn Reson Med 76:1764-1774
Thatcher, R W; Palmero-Soler, E; North, D M et al. (2016) Intelligence and eeg measures of information flow: efficiency and homeostatic neuroplasticity. Sci Rep 6:38890

Showing the most recent 10 out of 493 publications