This subproject is one of many research subprojects utilizing theresources provided by a Center grant funded by NIH/NCRR. The subproject andinvestigator (PI) may have received primary funding from another NIH source,and thus could be represented in other CRISP entries. The institution listed isfor the Center, which is not necessarily the institution for the investigator.This study investigated the spatio-temporal properties of blood-oxygenation level-dependent (BOLD) functional MRI (fMRI) signals in gray matter, excluding the confounding, inaccurate contributions of large blood vessels. We quantified the spatial specificity of the BOLD response, and we investigated whether this specificity varies as a function of time from stimulus onset. fMRI was performed at 7 Tesla (T), where mapping signals of parenchymal origin are easily detected. Two abutting visual stimuli were adjusted to elicit responses centered on a flat gray matter region in V1. fMRI signals were sampled at high-resolution orthogonal to the retinotopic boundary between the representations of the stimuli. Signals from macro-vessels were masked out. Principal component analysis revealed that the first component in space accounted for 96.2+/-1.6% of the variance over time. The spatial profile of this time-invariant response was fitted with a model consisting of the convolution of a step function and a Gaussian point-spread-function (PSF). The mean full-width at half-maximal-height of the fitted PSF was 2.34+/-0.20 mm. Based on simulations of confounding effects, we estimate that BOLD PSF in human gray matter is smaller than 2 mm. A time-point to time-point analysis revealed that the PSF obtained during the 3rd (1.52 mm) and 4th (1.99 mm) seconds of stimulation were narrower than the mean PSF obtained from the 5th second on (2.42+/-0.15 mm). The position of the edge of the responding region was offset (1.72+/-0.07 mm) from the boundary of the stimulated region, indicating a spatial non-linearity. Simulations showed that the effective contrast between active and non-active columns is reduced 25-fold when imaged using a PSF whose width is equal to the cycle of the imaged columnar organization. Thus, the PSF of the hyper-oxygenated BOLD response in human gray matter is narrower than that reported at 1.5 T, where macro-vessels dominate the mapping signals. The initial phase of this response is more spatially specific than later phases. Data acquisition methods that suppress macro-vascular signals should increase the spatial specificity of BOLD fMRI. The choice of optimal stimulus duration represents a trade-off between the spatial specificity and the overhead associated with short stimulus duration.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
2P41RR008079-16
Application #
7721359
Study Section
Special Emphasis Panel (ZRG1-SBIB-S (40))
Project Start
2008-06-01
Project End
2009-05-31
Budget Start
2008-06-01
Budget End
2009-05-31
Support Year
16
Fiscal Year
2008
Total Cost
$17,835
Indirect Cost
Name
University of Minnesota Twin Cities
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
555917996
City
Minneapolis
State
MN
Country
United States
Zip Code
55455
Herzberg, Max P; Hodel, Amanda S; Cowell, Raquel A et al. (2018) Risk taking, decision-making, and brain volume in youth adopted internationally from institutional care. Neuropsychologia 119:262-270
U?urbil, Kamil (2018) Imaging at ultrahigh magnetic fields: History, challenges, and solutions. Neuroimage 168:7-32
Foell, Jens; Palumbo, Isabella M; Yancey, James R et al. (2018) Biobehavioral threat sensitivity and amygdala volume: A twin neuroimaging study. Neuroimage 186:14-21
Magnitsky, Sergey; Pickup, Stephan; Garwood, Michael et al. (2018) Imaging of a high concentration of iron labeled cells with positive contrast in a rat knee. Magn Reson Med :
Lee, Byeong-Yeul; Zhu, Xiao-Hong; Woo, Myung Kyun et al. (2018) Interleaved 31 P MRS imaging of human frontal and occipital lobes using dual RF coils in combination with single-channel transmitter-receiver and dynamic B0 shimming. NMR Biomed 31:
Wilson, Sylia; Malone, Stephen M; Hunt, Ruskin H et al. (2018) Problematic alcohol use and hippocampal volume in a female sample: disentangling cause from consequence using a co-twin control study design. Psychol Med 48:1673-1684
Bolan, Patrick J; Kim, Eunhee; Herman, Benjamin A et al. (2017) MR spectroscopy of breast cancer for assessing early treatment response: Results from the ACRIN 6657 MRS trial. J Magn Reson Imaging 46:290-302
Nelson, Brent G; Bassett, Danielle S; Camchong, Jazmin et al. (2017) Comparison of large-scale human brain functional and anatomical networks in schizophrenia. Neuroimage Clin 15:439-448
Wang, Yi; Shao, Xingfeng; Martin, Thomas et al. (2016) Phase-cycled simultaneous multislice balanced SSFP imaging with CAIPIRINHA for efficient banding reduction. Magn Reson Med 76:1764-1774
Thatcher, R W; Palmero-Soler, E; North, D M et al. (2016) Intelligence and eeg measures of information flow: efficiency and homeostatic neuroplasticity. Sci Rep 6:38890

Showing the most recent 10 out of 493 publications