Introduction: The rapid decline in MRI detected apparent diffusion coefficient (ADC) of brain tissue during ischemia is thought to be due to cytotoxic edema following energy failure resulting from the cessation of blood flow. This study aims to correlate rapidly acquired ADC measurements with DC electrical potential (as an indicator of cell membrane polarization) during global ischemia by cardiac arrest. Methods: Male Sprague-Dawley rats were anesthetized with halothane. A chlorided silver electrode was placed on the cortex through a burr hole, to measure brain DC potentials. DC and MABP were recorded continuously. MRI was performed on a 2.0T GE Omega system using echo planar imaging. Diffusion and non-diffusion weighted images were alternated to measure ADC over the brain every 6 seconds. Three groups of animals were defined: normal, hyperglycemic and hypoglycemic. Images were acquired continuously before and up to 15 minutes after cardiac arrest by i.v. KCl injection. Results: MABP fell to zero within 5 seconds of KCl injection. ADC immediately began to decline slowly, followed by a sudden and large decline and then remained constant or declined slowly again until the end of the scan. The delay between MABP drop and the rapid ADC decline in each group was (mean1s.d. minutes): normal 1.4210.17 (n=7), hyperglycemic 2.8510.83 (n=5), hypoglycemic 0.9410.39 (n=5). Corresponding values for the DC drop were: normal 1.4210.8 (n=5), hyperglycemic 3.5010.76 (n=3), hypoglycemic 0.6210.17 (n=2). Conclusion: A gradual ADC decline begins immediately upon MABP decrease, which may be due to an instantaneous transmembrane water shift. A subsequent rapid drop in ADC occurs coincident with anoxic cell membrane depolarization; both changes were delayed or accelerated together by hyper- or hypoglycemia.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
3P41RR009784-05S1
Application #
6309989
Study Section
Project Start
1999-01-01
Project End
2000-07-31
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
5
Fiscal Year
2000
Total Cost
$15,525
Indirect Cost
Name
Stanford University
Department
Type
DUNS #
800771545
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Suh, Ga-Young; Choi, Gilwoo; Herfkens, Robert J et al. (2016) Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration. Ann Vasc Surg 34:250-60
Ong, Frank; Lustig, Michael (2016) Beyond Low Rank + Sparse: Multi-scale Low Rank Matrix Decomposition. IEEE J Sel Top Signal Process 10:672-687

Showing the most recent 10 out of 446 publications