Fractures of the thoracolumbar region of the spine are serious disabling injuries, resulting in personal suffering and significant loss to society. Short segment fixations (pedicle screw and anterior devices) are increasing rapidly in use, and have the advantage of immobilizing only the minimum necessary number of spinal segments. There are two aspects of these devices that are clinically important: reduction of spinal canal and intervertebral foramen encroachments and stabilization of the fractured spine. The strength of the spinal devices has been studied. However, their capability to stabilize the spine in multiple physiological directions is often left out from experimental studies. Device failures are not uncommon, but the failure may be less related to the device strength than to its ability to stabilize. Stability of the fracture site is necessary to enhance the chances of early fusion, thus unloading the device and prevention of its failure. There are no biomechanical studies, using a realistic thoracolumbar burst fracture model, that have studied the adjustments of the short segment fixation devices to both optimize the spinal canal and intervertebral foramen encroachments, and the multidirectional stability provided by the devices. Fresh thoracolumbar human spine specimens will be subjected to high speed trauma that will result in clinically relevant burst fractures. Utilizing a unique incremental trauma approach, the applicants will produce burst fractures of varying severities. Using an innovative model to study a generic short segment device, general criteria for reducing the spinal canal and intervertebral foramen encroachment will be established. Additional experiments will be conducted with specific anterior and posterior devices to determine clinically relevant guidelines for their optimal use. On a comparative basis, the applicants will study the restoration of multidirectional stability of burst fractures of varying severities by the application of anterior and posterior devices, alone and when combined. Pedicle fixation devices are increasing in popularity, but there is concern from government agencies and controversy among orthopaedic and neurosurgical spine surgeons regarding their efficacy and safety. Biomechanical studies can provide objective data to help resolve these controversies. The proposed applicants suggest that the studies optimize one of the most frequently used surgical procedures for spinal fixation. They feel that the findings will result in objective guidelines for the surgeon and treatment benefits for the patient. Clinical relevance is the primary aim of the study, and it may help in the health care cost containment at the level of treatment.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
5R01AR039209-08
Application #
2712436
Study Section
Orthopedics and Musculoskeletal Study Section (ORTH)
Project Start
1989-12-01
Project End
2000-05-31
Budget Start
1998-06-01
Budget End
1999-05-31
Support Year
8
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Yale University
Department
Orthopedics
Type
Schools of Medicine
DUNS #
082359691
City
New Haven
State
CT
Country
United States
Zip Code
06520
Wang, Jaw-Lin; Panjabi, Manohar M; Kato, Yoshihiko et al. (2002) Radiography cannot examine disc injuries secondary to burst fracture: quantitative discomanometry validation. Spine (Phila Pa 1976) 27:235-40
Oda, T; Panjabi, M M; Kato, Y (2001) The effects of pedicle screw adjustments on the anatomical reduction of thoracolumbar burst fractures. Eur Spine J 10:505-11
Oda, T; Panjabi, M M (2001) Pedicle screw adjustments affect stability of thoracolumbar burst fracture. Spine (Phila Pa 1976) 26:2328-33
Panjabi, M M; Kato, Y; Hoffman, H et al. (2001) Canal and intervertebral foramen encroachments of a burst fracture: effects from the center of rotation. Spine (Phila Pa 1976) 26:1231-7
Panjabi, M M; Hoffman, H; Kato, Y et al. (2000) Superiority of incremental trauma approach in experimental burst fracture studies. Clin Biomech (Bristol, Avon) 15:73-8
Panjabi, M M; Kato, Y; Hoffman, H et al. (2000) A study of stiffness protocol as exemplified by testing of a burst fracture model in sagittal plane. Spine (Phila Pa 1976) 25:2748-54
Panjabi, M M; Oda, T; Wang, J L (2000) The effects of pedicle screw adjustments on neural spaces in burst fracture surgery. Spine (Phila Pa 1976) 25:1637-43
Isomi, T; Panjabi, M M; Kato, Y et al. (2000) Radiographic parameters for evaluating the neurological spaces in experimental thoracolumbar burst fractures. J Spinal Disord 13:404-11
Nibu, K; Panjabi, M M; Oxland, T et al. (1998) Intervertebral disc distraction with a laparoscopic anterior spinal fusion system. Eur Spine J 7:142-7
Vahldiek, M J; Panjabi, M M (1998) Stability potential of spinal instrumentations in tumor vertebral body replacement surgery. Spine (Phila Pa 1976) 23:543-50

Showing the most recent 10 out of 38 publications