The overall goal of this renewal application is to improve the effectiveness of positron emisskm tomography (PET) imaging for the diagnosis and treatment of patients with cancer. The proposed research will compare the performance of several alternative scanner designs for tumor quantitation and detection tasks commonly performed in our clinical and research PET protocols. The target applications include tumor imaging in the breast and torso using 18F-estradiol, '8FDG, and """"""""C-thymidine, for tumor detection and staging, therapy planning, and monitoring response to therapy. The scanner designs considered will include existing 2D and 3D systems, as well as new designs with varying axial and radial extent, coarse collimation, and different scintillator materials. Additional research will evaluate the difficulties confronting PET using several isotopes that have recently attracted significant interest for a variety of applications, but which decay by complicated pathways and produce background radiation (e.g. increased randoms, septal penetration, and, for some isotopes, pair production) that ultimately contaminates the image data. Methods to compensate for these effects will be developed and evaluated. The applications for the isotopes considered, 86Y, 1241, and 94mTc, include therapy planning prior to treatment with monoclonal antibodies and cross-validation studies for quantitative SPECT performed with 99mTc-based compounds. As part of previous research conducted at the University of Washington, a Simulation System for Emission Tomography (SimSET) was developed. This Monte Carlo-based software package tracks photons through complex heterogeneous objects (patients) and models the effects of collimation and detection. The research proposed in this application will require several improvements and extensions to SimSET. New tools to automate the measurement of image quality will be added. A number of new acceleration techniques will be incorporated, as well as models for additional physical effects. This work, along with continuing efforts to make the software easier to use, will also support ongoing research by the many other investigators using SimSET at other institutions. The SimSET software package is freely available via the Internet.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA042593-18
Application #
7028260
Study Section
Diagnostic Imaging Study Section (DMG)
Program Officer
Baker, Houston
Project Start
1987-07-01
Project End
2007-03-31
Budget Start
2006-04-01
Budget End
2007-03-31
Support Year
18
Fiscal Year
2006
Total Cost
$329,383
Indirect Cost
Name
University of Washington
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
605799469
City
Seattle
State
WA
Country
United States
Zip Code
98195
Zuki?, Dženan; Byrd, Darrin W; Kinahan, Paul E et al. (2018) Calibration Software for Quantitative PET/CT Imaging Using Pocket Phantoms. Tomography 4:148-158
Kinahan, Paul E; Byrd, Darrin W; Helba, Brian et al. (2018) Simultaneous Estimation of Bias and Resolution in PET Images With a Long-Lived ""Pocket"" Phantom System. Tomography 4:33-41
Zeng, Chengeng; Kinahan, Paul E; Qian, Hua et al. (2017) Simulation study of quantitative precision of the PET/X dedicated breast PET scanner. J Med Imaging (Bellingham) 4:045502
Lee, Tzu C; Alessio, Adam M; Miyaoka, Robert M et al. (2016) Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging. Q J Nucl Med Mol Imaging 60:25-39
Gong, Kuang; Majewski, Stan; Kinahan, Paul E et al. (2016) Designing a compact high performance brain PET scanner-simulation study. Phys Med Biol 61:3681-97
McDougald, Wendy A; Miyaoka, Robert S; Alessio, Adam M et al. (2016) A study of SPECT/CT camera stability for quantitative imaging. EJNMMI Phys 3:14
Vaquero, Juan José; Kinahan, Paul (2015) Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems. Annu Rev Biomed Eng 17:385-414
Harrison, Robert L; Elston, Brian F; Doot, Robert K et al. (2014) A Virtual Clinical Trial of FDG-PET Imaging of Breast Cancer: Effect of Variability on Response Assessment. Transl Oncol 7:138-46
MacDonald, L R; Harrison, R L; Alessio, A M et al. (2011) Effective count rates for PET scanners with reduced and extended axial field of view. Phys Med Biol 56:3629-43
Harrison, Robert L (2010) Introduction To Monte Carlo Simulation. AIP Conf Proc 1204:17-21

Showing the most recent 10 out of 32 publications