The technology of active matrix flat-panel imagers (AMFPIs) has undergone extensive research and development for many x-ray imaging applications since its initial conception in the 1980s. As a result, electronic portal imaging devices (EPIDs) based on AMFPI technology have been extensively introduced to external beam radiotherapy environments. Megavoltage AMFPIs represent a highly compact, large area (up to -41x41 cm2), solid-state technology that can be used for radiographic, fluoroscopic and tomographic imaging. In radiographic mode, image quality is substantially improved compared to that of the previous """"""""gold standard"""""""", standard port film. However, present AMFPIs make use of only -2% of the incident radiation, the result is that their detective quantum efficiency (DQE - a widely accepted observer independent measure of imager performance), although equivalent to or higher than that of other commercial portal imaging technologies, is still only -1%. Thus, significant improvements in DQE and image quality are possible. Consequently, the hypothesis to be examined in the proposed research is: """"""""Through the incorporation of innovative strategies, the DQE of megavoltage AMFPIs can be substantially increased through more efficient use of the incident radiation."""""""" Two approaches for increasing DQE (by factors ranging from ~6 to 50) involving photoconductor and segmented crystalline scintillator technologies will be investigated, each of which offers the potential of significantly increasing x-ray detection efficiency while limiting both the spatial spread of secondary quanta as well as the generation of noise in those quanta. Ultimately, the clinical introduction of AMFPIs offering such significantly enhanced DQE would reduce the dose required for projection images to low, potentially negligible levels, provide soft-tissue contrast in tomographic images at clinically-practical doses, and possibly provide soft-tissue contrast in projection images at clinically-practical doses, thereby greatly assisting in the difficult task of treatment verification.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA051397-14
Application #
7619001
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Deye, James
Project Start
1990-02-01
Project End
2012-05-31
Budget Start
2009-06-01
Budget End
2012-05-31
Support Year
14
Fiscal Year
2009
Total Cost
$510,453
Indirect Cost
Name
University of Michigan Ann Arbor
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
073133571
City
Ann Arbor
State
MI
Country
United States
Zip Code
48109
El-Mohri, Youcef; Antonuk, Larry E; Choroszucha, Richard B et al. (2014) Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques. Phys Med Biol 59:797-818
Liu, Langechuan; Antonuk, Larry E; El-Mohri, Youcef et al. (2014) Optimization of the design of thick, segmented scintillators for megavoltage cone-beam CT using a novel, hybrid modeling technique. Med Phys 41:061916
Jiang, Hao; Zhao, Qihua; Antonuk, Larry E et al. (2013) Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging. Phys Med Biol 58:703-14
Liu, Langechuan; Antonuk, Larry E; Zhao, Qihua et al. (2012) Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers. Phys Med Biol 57:5343-58
El-Mohri, Youcef; Antonuk, Larry E; Zhao, Qihua et al. (2011) Low-dose megavoltage cone-beam CT imaging using thick, segmented scintillators. Phys Med Biol 56:1509-27
Zhao, Qihua; Antonuk, Larry E; El-Mohri, Youcef et al. (2010) Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging. Med Phys 37:2738-48
Wang, Yi; El-Mohri, Youcef; Antonuk, Larry E et al. (2010) Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging. Phys Med Biol 55:3659-73
Wang, Yi; Antonuk, Larry E; Zhao, Qihua et al. (2009) High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose. Med Phys 36:5707-18
Wang, Yi; Antonuk, Larry E; El-Mohri, Youcef et al. (2009) A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging. Med Phys 36:3227-38
Wang, Yi; Antonuk, Larry E; El-Mohri, Youcef et al. (2008) Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization. Med Phys 35:145-58

Showing the most recent 10 out of 23 publications