To study dosimetric effects in time-dependent geometries the results of individual three-dimensional (3D) calculations are usually added or statistically combined. This is cumbersome if the geometry is complex, if high time resolution is envisaged (e.g. considering dose rate), or if the microscopic volume displacement as a function of time is not known. Furthermore, it is difficult to study double-dynamic systems to investigate the influence of time-dependent beam delivery (moving leafs in a multi-leaf collimator) on the dose deposition in a moving target (organ motion or deformation). Here, 4D instead of multiple 3D calculations are required. Monte Carlo (MC) simulations are believed to be the most accurate tool for dose calculation and wiII presumably have the biggest impact in areas of large density variations, e.g. for lung cancer treatments. Interestingly, this is also the area where we might expect the biggest impact of organ motion on the dose distribution. The MC method is well suited to study dosimetric effects of motion with high accuracy. However, until now, like for analytical dose calculation techniques, the geometric information cannot be modified during the simulation. This limits applications to multiple 3D instead of true 4D. In taking advantage of objejctoriented C++ programming techniques we are proposing true 4D MC dose calculation. Local dose deposition in the patient will be calculated while beam configuration and organ geometry are changed continuously MLC leaf positions will be changing during the simulation according to leaf sequencing files. Based on deformable image registration we will track microscopic areas based on the patient's CT during the dose calculation. 4D dose calculation will allow the usage of a preset moving pattern based on clinical experience or patient specific 4D CT information. The capability of studying time dependent geometries and the interplay in double-dynamic systems for any time scale based on treatment head variations and patient's breathing pattern will take MC dose calculation to a new level, to the level of 4D treatment simulation.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA111590-04
Application #
7394459
Study Section
Radiation Therapeutics and Biology Study Section (RTB)
Program Officer
Deye, James
Project Start
2005-07-01
Project End
2010-04-30
Budget Start
2008-05-01
Budget End
2010-04-30
Support Year
4
Fiscal Year
2008
Total Cost
$249,727
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
02199
Dowdell, Stephen; Grassberger, Clemens; Sharp, Greg et al. (2016) Fractionated Lung IMPT Treatments: Sensitivity to Setup Uncertainties and Motion Effects Based on Single-Field Homogeneity. Technol Cancer Res Treat 15:689-96
Grassberger, Clemens; Dowdell, Stephen; Sharp, Greg et al. (2015) Motion mitigation for lung cancer patients treated with active scanning proton therapy. Med Phys 42:2462-9
Grassberger, C; Lomax, Anthony; Paganetti, H (2015) Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients. Phys Med Biol 60:633-45
Phillips, Justin; Gueorguiev, Gueorgui; Shackleford, James A et al. (2014) Computing proton dose to irregularly moving targets. Phys Med Biol 59:4261-73
Grassberger, Clemens; Daartz, Juliane; Dowdell, Stephen et al. (2014) Quantification of proton dose calculation accuracy in the lung. Int J Radiat Oncol Biol Phys 89:424-30
Dowdell, S; Grassberger, C; Sharp, G C et al. (2013) Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters. Phys Med Biol 58:4137-56
Grassberger, Clemens; Dowdell, Stephen; Lomax, Antony et al. (2013) Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer. Int J Radiat Oncol Biol Phys 86:380-6
Dowdell, Stephen; Grassberger, Clemens; Paganetti, Harald (2013) Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments. Med Phys 40:121713
McGurk, Ross; Seco, Joao; Riboldi, Marco et al. (2010) Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo. Phys Med Biol 55:1475-90
Nohadani, Omid; Seco, Joao; Martin, Benjamin C et al. (2009) Dosimetry robustness with stochastic optimization. Phys Med Biol 54:3421-32

Showing the most recent 10 out of 14 publications