Radiofrequency (RF) ablation is a promising, minimally invasive heat-based method used to ablate cancer of the liver, kidney, bone, and lung. Under imaging guidance, an electrode is inserted into the tumor, and radiofrequency current is applied to the electrode resulting in ionic agitation and tissue heating. The tumor is destroyed by coagulative necrosis once it reaches >50 ?C. One of the major advantages of RF ablation is that it can be applied in a minimally invasive fashion, resulting in rapid patient recovery and low morbidity. Initial RF devices used 25 W power and created 1.5 cm diameter coagulation zones, while current devices use 200 - 250 W power and create 4-6 cm diameter coagulation zones. One major limitation of current RF devices is the inability to treat even moderate size tumors (>3 cm) with a single ablation due to insufficient size of the coagulation zone. Therefore future devices will likely continue the trend towards higher generator power and multiple electrodes to increase the size of coagulation zone and decrease treatment times. A major obstacle in employing higher power RF generators and enabling increased coagulation zones is ground pad heating, which can lead to 3rd degree skin burns in severe cases. The current incidence of ground pad skin burns ranges from 0.1 - 3.2 % for severe skin burns (2nd or 3rd degree), with mild skin burns ranging between 5-33 %. Due to inhomogeneous distribution of RF current below the ground pads, the edge closest to the electrode is where the highest skin temperatures and burns are most likely occur. In clinical ablation procedures, two-to-four ground pads are placed equidistant from the ablation electrode, usually around the thighs. Adding additional ground pads further away from the electrode will only provide minimal improvement, since RF current travels preferentially to the closest pads. Attempts in reducing ground pad related heating so far have been limited to optimizing pad placement, pad shape, and cooling of the pads. We propose to modulate the RF current and associated heating below each pad by sequentially activating ground pads, and adding a layer of electrically conductive gel below the pads. Thereby RF current is distributed evenly among multiple pads, related heating is reduced, and pads can be placed arbitrarily without the current limitation of being at the same distance from the RF electrode. This method will enable higher generator power, and reduce the likelihood of skin burns. Relevance of this project to public health: Successful completion of this project will enable more effective treatment of liver cancer. Physicians will be able to treat larger tumors, treatment times will be reduced, and success rates may increase.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA118990-03
Application #
7633342
Study Section
Special Emphasis Panel (ZRG1-SBIB-L (90))
Program Officer
Farahani, Keyvan
Project Start
2007-07-01
Project End
2011-05-31
Budget Start
2009-06-01
Budget End
2010-05-31
Support Year
3
Fiscal Year
2009
Total Cost
$222,528
Indirect Cost
Name
Medical University of South Carolina
Department
Pediatrics
Type
Schools of Medicine
DUNS #
183710748
City
Charleston
State
SC
Country
United States
Zip Code
29425
Rossmann, Christian; Garrett-Mayer, Elizabeth; Rattay, Frank et al. (2014) Dynamics of tissue shrinkage during ablative temperature exposures. Physiol Meas 35:55-67
Reddy, Goutham; Dreher, Matthew R; Rossmann, Christian et al. (2013) Cytotoxicity of hepatocellular carcinoma cells to hyperthermic and ablative temperature exposures: in vitro studies and mathematical modelling. Int J Hyperthermia 29:318-23
Gasselhuber, Astrid; Dreher, Matthew R; Rattay, Frank et al. (2012) Comparison of conventional chemotherapy, stealth liposomes and temperature-sensitive liposomes in a mathematical model. PLoS One 7:e47453
Gasselhuber, Astrid; Dreher, Matthew R; Partanen, Ari et al. (2012) Targeted drug delivery by high intensity focused ultrasound mediated hyperthermia combined with temperature-sensitive liposomes: computational modelling and preliminary in vivovalidation. Int J Hyperthermia 28:337-48
Haemmerich, Dieter; Schutt, David J (2011) RF ablation at low frequencies for targeted tumor heating: in vitro and computational modeling results. IEEE Trans Biomed Eng 58:404-10
Schutt, David J; Swindle, M Michael; Helke, Kristi L et al. (2010) Sequential activation of ground pads reduces skin heating during radiofrequency tumor ablation: in vivo porcine results. IEEE Trans Biomed Eng 57:746-53
Haemmerich, Dieter (2010) Mathematical modeling of impedance controlled radiofrequency tumor ablation and ex-vivo validation. Conf Proc IEEE Eng Med Biol Soc 2010:1605-8
Schutt, David J; Swindle, M Michael; Bastarrika, Gorka A et al. (2009) Sequential activation of ground pads reduces skin heating during radiofrequency ablation: initial in vivo porcine results. Conf Proc IEEE Eng Med Biol Soc 2009:4287-90
Dos Santos, Icaro; Haemmerich, Dieter; Schutt, David et al. (2009) Probabilistic finite element analysis of radiofrequency liver ablation using the unscented transform. Phys Med Biol 54:627-40
Schutt, David J; Haemmerich, Dieter (2008) Sequential activation of a segmented ground pad reduces skin heating during radiofrequency tumor ablation: optimization via computational models. IEEE Trans Biomed Eng 55:1881-9

Showing the most recent 10 out of 13 publications