Persons with recent hand amputations expect modern hand prostheses to function like intact hands. Current state-of-the-art electric prosthetic hands are generally single degree-of-freedom (opening and closing) devices that are controlled using only two muscle signals. As a result, most state-of-the-art devices fail to meet user's expectations and are under-utilized or rejected. Because of this, advances in mechanical hardware are directed toward providing functionality comparable to the intact human hand. Despite such advances, the performance of sophisticated hand prostheses remains limited by the ability to control them via physiological (e.g., electromyographic) signals sensed from the user. In general, prosthetic devices that support multiple degree-of-freedom movements for any limb require sequential control, implementing locking mechanisms or special switch signals to change from one degree-of-freedom to another. There is a large, unmet need for control algorithms that allow simultaneous control of multiple degrees-of-freedom and are not difficult for the user to learn. In this study, we will implement a biomechanical modeling approach to develop a control algorithm that predicts the hand and wrist motions that would occur in an intact hand given the electromyographic (EMG) signals measured from the residual muscles of an amputee's forearm. The objectives for this proposal are to first characterize the function of the hand muscles in creating complex hand motions in the intact hand and to then develop the controller. To accomplish these objectives, extrinsic muscle activity and joint kinematics will be quantified as individuals produce a subset of postures from the manual alphabet of American Sign Language (ASL), and perform two prehensile tasks. Recorded muscle activity will define the control signals available from the extrinsic muscles during complex motions, and will become input for biomechanical simulations, which will be used to identify how effectively postures can be achieved without the contributions from the intrinsic muscles of the hand (the subset of muscles lost to amputation). Results will direct the mechanical design of prosthetic hands to effectively compensate for the mechanical actions of the missing intrinsic muscles. Ultimately, a prosthetic hand is intended to be used to manipulate objects. Thus, we will implement recent developments in variational integration theory to develop real-time simulations that incorporate endpoint forces, such as those found when the fingertips are in contact with an object, and other constraints required to simulate the hand interacting with external objects. Upon completion of the simulation work, a controller that drives the artificial hand based on user-generated muscle signals will be developed and implemented. Accomplishing the goals of this project will address a critical barrier to clinical implementation and user acceptance of multi-function prosthetic hands.

Public Health Relevance

At its core, this project aims to deliver a real-time simulator of complex, multi-degree of freedom human hand motions, and link it to the hardware necessary to control state-of-the-art multi-function artificial hands. Such a system will enable the evaluation of many different approaches to the control of hand prostheses, facilitate the study of motor control of hand movement, and will have applications to rehabilitation of hand function in many populations, such as spinal cord injury and stroke.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB011615-02
Application #
8252162
Study Section
Modeling and Analysis of Biological Systems Study Section (MABS)
Program Officer
Peng, Grace
Project Start
2011-04-05
Project End
2015-03-31
Budget Start
2012-04-01
Budget End
2013-03-31
Support Year
2
Fiscal Year
2012
Total Cost
$436,195
Indirect Cost
$122,153
Name
Rehabilitation Institute of Chicago
Department
Type
DUNS #
068477546
City
Chicago
State
IL
Country
United States
Zip Code
60611
Nichols, Jennifer A; Bednar, Michael S; Wohlman, Sarah J et al. (2017) Connecting the wrist to the hand: A simulation study exploring changes in thumb-tip endpoint force following wrist surgery. J Biomech 58:97-104
Binder-Markey, Benjamin I; Murray, Wendy M (2017) Incorporating the length-dependent passive-force generating muscle properties of the extrinsic finger muscles into a wrist and finger biomechanical musculoskeletal model. J Biomech 61:250-257
Gracia-Ibáñez, Verónica; Vergara, Margarita; Buffi, James H et al. (2017) Across-subject calibration of an instrumented glove to measure hand movement for clinical purposes. Comput Methods Biomech Biomed Engin 20:587-597
Blana, Dimitra; Chadwick, Edward K; van den Bogert, Antonie J et al. (2017) Real-time simulation of hand motion for prosthesis control. Comput Methods Biomech Biomed Engin 20:540-549
Buffi, James H; Werner, Katie; Kepple, Tom et al. (2015) Computing muscle, ligament, and osseous contributions to the elbow varus moment during baseball pitching. Ann Biomed Eng 43:404-15
Saul, Katherine R; Hu, Xiao; Goehler, Craig M et al. (2015) Benchmarking of dynamic simulation predictions in two software platforms using an upper limb musculoskeletal model. Comput Methods Biomech Biomed Engin 18:1445-58
Wilson, Andrew D; Schultz, Jarvis A; Murphey, Todd D (2014) Trajectory Synthesis for Fisher Information Maximization. IEEE Trans Robot 30:1358-1370
Buffi, James H; Sancho Bru, Joaquín Luis; Crisco, Joseph J et al. (2014) Evaluation of hand motion capture protocol using static computed tomography images: application to an instrumented glove. J Biomech Eng 136:124501
Wilson, Andrew D; Murphey, Todd D (2014) Local E-optimality Conditions for Trajectory Design to Estimate Parameters in Nonlinear Systems. Proc Am Control Conf 2014:443-450
Buffi, James H; Crisco, Joseph J; Murray, Wendy M (2013) A method for defining carpometacarpal joint kinematics from three-dimensional rotations of the metacarpal bones captured in vivo using computed tomography. J Biomech 46:2104-8

Showing the most recent 10 out of 12 publications