The long-term goal of our research program is to understand how optical and retinal factors constrain the quality of visual experience. In central vision, poor optical quality of the eye is the chief cause of poor visual performance on many visual tasks, especially in clinically abnormal eyes. We propose to use newly developed technologies to investigate the underlying physiological mechanisms which are responsible for these optical limitations to vision. The results will improve our understanding of the optical consequences of clinical conditions such as dry eye and keratoconus, which may ultimately lead to new diagnostic and treatment strategies.
Aim 1 is to test the hypothesis that the corneal tear film provides an optically smooth refracting surface which reduces light scatter and refractive aberrations that would otherwise degrade the retinal image and reduce visual performance. This hypothesis predicts that disruption of the tear film by blink suppression will expose the underlying rough, irregular surface of the cornea, thereby increasing light scatter and refractive aberrations which will degrade the retinal image. The predicted outcome is blurry vision and reduced visual performance. To test these predictions we will use a Shack-Hartmann aberrometer to objectively measure refractive aberration and light scatter simultaneously at 200 or more points in the eye's pupil. The results will be compared with topographic maps of tear film disruption obtained simultaneously by fluorescein and by retro-illumination imaging of the pupil. Image quality will also be compared with visual acuity and contrast sensitivity during tear film disruption.
Aim 2 is to test the hypothesis that corneal shape is responsible for the majority of the eye's refractive aberrations. In the process, we also aim to resolve the current controversy over whether optical aberrations due to corneal shape compensate or exacerbate the aberrations of the remaining optical elements of the eye. This hypothesis will be tested in normal eyes and in clinical patients with highly abnormal corneal shape caused by the corneal disease keratoconus. We will measure the aberrations of the cornea with topographic videokeratoscopy for comparison against aberrations of the whole eye measured with the Shack-Hartmann aberrometer. The effect of corneal aberrations and scatter in keratoconic eyes on visual performance will also be measured by using simulated retinal images computed with an optical model of the keratoconic eye as visual stimuli for normal eyes.
Aim 3 is to develop a comprehensive, quantitative optical model of the eye which accounts for constraints on retinal image quality and on visual performance imposed by optical imperfections of the eye. Results from our studies of the optical function of the tear film and cornea will be incorporated in to the optical model to provide a quantitative, functional description of the effect of the eye's optical imperfections on retinal image quality and on visual performance in normals, dry-eye patients, and keratoconus patients.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Research Project (R01)
Project #
5R01EY005109-20
Application #
6721426
Study Section
Visual Sciences B Study Section (VISB)
Program Officer
Oberdorfer, Michael
Project Start
1984-01-01
Project End
2006-07-31
Budget Start
2004-04-01
Budget End
2006-07-31
Support Year
20
Fiscal Year
2004
Total Cost
$223,500
Indirect Cost
Name
Indiana University Bloomington
Department
Type
Schools of Optometry/Ophthalmol
DUNS #
006046700
City
Bloomington
State
IN
Country
United States
Zip Code
47401
Wilkinson, Michael O; Anderson, Roger S; Bradley, Arthur et al. (2016) Neural bandwidth of veridical perception across the visual field. J Vis 16:1
Ravikumar, Sowmya; Bradley, Arthur; Bharadwaj, Shrikant et al. (2016) Expanding binocular depth of focus by combining monovision with diffractive bifocal intraocular lenses. J Cataract Refract Surg 42:1288-1296
Bradley, Arthur; Nam, Jayoung; Xu, Renfeng et al. (2014) Impact of contact lens zone geometry and ocular optics on bifocal retinal image quality. Ophthalmic Physiol Opt 34:331-45
Ravikumar, Sowmya; Bradley, Arthur; Thibos, Larry N (2014) Chromatic aberration and polychromatic image quality with diffractive multifocal intraocular lenses. J Cataract Refract Surg 40:1192-204
Teel, Danielle F W; Jacobs, Robert J; Copland, James et al. (2014) Differences between wavefront and subjective refraction for infrared light. Optom Vis Sci 91:1158-66
Coe, Charles; Bradley, Arthur; Thibos, Larry (2014) Polychromatic refractive error from monochromatic wavefront aberrometry. Optom Vis Sci 91:1167-74
Bradley, Arthur; Xu, Renfeng; Thibos, Larry et al. (2014) Influence of spherical aberration, stimulus spatial frequency, and pupil apodisation on subjective refractions. Ophthalmic Physiol Opt 34:309-20
López-Gil, Norberto; Martin, Jesson; Liu, Tao et al. (2013) Retinal image quality during accommodation. Ophthalmic Physiol Opt 33:497-507
Thibos, Larry N; Bradley, Arthur; Liu, Tao et al. (2013) Spherical aberration and the sign of defocus. Optom Vis Sci 90:1284-91
Thibos, Larry N (2013) The 2012 Charles Prentice medal lecture: wavefront measurement of refractive state. Optom Vis Sci 90:911-23

Showing the most recent 10 out of 71 publications