The goal of this proposal is the continued development of DNA sequencing by charge reduction electrospray ionization. The research presented here focuses on the development of new techniques for the generation ionization and sampling of gas-phase biomolecular ions. The combination of these techniques holds the potential to produce a l0,000 fold increase in sensitivity over conventional electrospray. Single droplets will be generated by a piezoelectric dispenser and held in an electrodynamic trap where they will be desolvated by a flow of bath gas to produce analyte ions. The analyte ions will leave the trap along a defined trajectory to enter a charge reduction chamber incorporating aerodynamic lensing. The aerodynamic lens system will replace the standard nozzle-skimmer and collisional cooling systems commonly employed in ESI-TOF. The fact that the ions will travel along a single defined trajectory, rather than along a multitude of trajectories as in conventional electrospray will permit time collection efficiency of the ions into time mass spectrometer to be greatly increased. In principle, the efficiency with which ions are introduced mass spectrometer may approach unity representing an approximately 10,000 fold increase over conventional electrospray. Additionally techniques to increase the ionization efficiency of DNA through gas phase reactions and charge tagging will be researched. The focus of this proposal will be the implementation of the basic concepts outlined above. To this end we will utilize aim existing ESI-TOF mass spectrometer (Perseptive Biosystems Mariner an orthogonal-TOF design) in our laboratory. The use of this existing instrument will eliminate the need to design and build an entirely new mass spectrometer from scratch while permitting dramatic improvements in nmass spectrometric performance.

Agency
National Institute of Health (NIH)
Institute
National Human Genome Research Institute (NHGRI)
Type
Research Project (R01)
Project #
5R01HG001808-05
Application #
6621837
Study Section
Special Emphasis Panel (ZRG1-BECM (01))
Program Officer
Graham, Bettie
Project Start
1998-07-01
Project End
2004-11-30
Budget Start
2002-12-01
Budget End
2003-11-30
Support Year
5
Fiscal Year
2003
Total Cost
$327,375
Indirect Cost
Name
University of Wisconsin Madison
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
161202122
City
Madison
State
WI
Country
United States
Zip Code
53715
Peelen, Dora; Kodoyianni, Voula; Lee, Jieun et al. (2006) Specific capture of mammalian cells by cell surface receptor binding to ligand immobilized on gold thin films. J Proteome Res 5:1580-5
Frey, Brian L; Lin, Yuan; Westphall, Michael S et al. (2005) Controlling gas-phase reactions for efficient charge reduction electrospray mass spectrometry of intact proteins. J Am Soc Mass Spectrom 16:1876-87
Chen, Xiaoyu; Westphall, Michael S; Smith, Lloyd M (2003) Mass spectrometric analysis of DNA mixtures: instrumental effects responsible for decreased sensitivity with increasing mass. Anal Chem 75:5944-52
Berggren, W Travis; Westphall, Michael S; Smith, Lloyd M (2002) Single-pulse nanoelectrospray ionization. Anal Chem 74:3443-8
Ebeling, D D; Westphall, M S; Scalf, M et al. (2001) A cylindrical capacitor ionization source: droplet generation and controlled charge reduction for mass spectrometry. Rapid Commun Mass Spectrom 15:401-5
Scalf, M; Westphall, M S; Smith, L M (2000) Charge reduction electrospray mass spectrometry. Anal Chem 72:52-60
Ebeling, D D; Westphall, M S; Scalf, M et al. (2000) Corona discharge in charge reduction electrospray mass spectrometry. Anal Chem 72:5158-61
Scalf, M; Westphall, M S; Krause, J et al. (1999) Controlling charge states of large ions. Science 283:194-7