The goal of this work is to investigate novel acquisition and reconstruction strategies to significantly increase the performance of contrast-enhanced magnetic resonance angiography (CE-MRA). Though CE- MRA is less invasive than X-ray angiography (XRA) and utilizes no ionizing radiation, XRA has considerably higher spatial and temporal resolution.
Our aim i s to develop, optimize, and evaluate new methods using projection reconstruction (PR) techniques that deliver higher spatial resolution per unit time than conventional Fourier k-space traversals. Efficiency will be increased by limiting the number of projection angles acquired. Sparse sampling in X-ray computed tomography (CT) using filtered back projection (FBP) produces """"""""clutter"""""""" artifacts which are large relative to the small differences in tissue attenuation displayed by CT. Preliminary results suggest that the large signal difference between enhanced vessels and static tissue in CE-MRA make these PR artifacts acceptable in some applications. Since the vessels generate the clutter artifacts, estimates of the artifacts can be generated and later reduced in post-processing. This PR strategy provides a preliminary four-fold reduction in scan time. Coupled with k-space scheduling and reconstruction methods for high temporal resolution, high spatial resolution can be provided at several key time frames throughout the arterial contrast enhancement curve. Three main 3DPR acquisition techniques will be developed to provide flexibility when prescribing spatial and temporal resolution. The proposed work includes simulations and phantom experiments to optimize the acquisition strategies and quantify their performance. Algorithms for artifact reduction will be further investigated and refined during these experiments as well. The optimized techniques will be clinically evaluated in the carotid arteries, lungs and abdomen. Successful completion of this work will place CE-MRA as a stronger competitor to the more invasive X-ray DSA technique.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL062425-03
Application #
6390311
Study Section
Special Emphasis Panel (ZRG1-DMG (01))
Program Officer
Altieri, Frank
Project Start
1999-04-01
Project End
2002-03-31
Budget Start
2001-04-01
Budget End
2002-03-31
Support Year
3
Fiscal Year
2001
Total Cost
$290,798
Indirect Cost
Name
University of Wisconsin Madison
Department
Physics
Type
Schools of Medicine
DUNS #
161202122
City
Madison
State
WI
Country
United States
Zip Code
53715
Du, Jiang; Lu, Aiming; Block, Walter F et al. (2005) Time-resolved undersampled projection reconstruction magnetic resonance imaging of the peripheral vessels using multi-echo acquisition. Magn Reson Med 53:730-4
Du, J; Thornton, F J; Fain, S B et al. (2004) Artifact reduction in undersampled projection reconstruction MRI of the peripheral vessels using selective excitation. Magn Reson Med 51:1071-6
Du, J; Korosec, F R; Thornton, F J et al. (2004) High-resolution multistation peripheral MR angiography using undersampled projection reconstruction imaging. Magn Reson Med 52:204-8
Du, J; Carroll, T J; Block, W F et al. (2003) SNR improvement for multiinjection time-resolved high-resolution CE-MRA of the peripheral vasculature. Magn Reson Med 49:909-17
Mazaheri, Yousef; Carroll, Timothy J; Du, Jiang et al. (2002) Combined time-resolved and high-spatial-resolution 3D MRA using an extended adaptive acquisition. J Magn Reson Imaging 15:291-301
Du, J; Carroll, T J; Wagner, H J et al. (2002) Time-resolved, undersampled projection reconstruction imaging for high-resolution CE-MRA of the distal runoff vessels. Magn Reson Med 48:516-22
Barger, Andrew V; Block, Walter F; Toropov, Yuriy et al. (2002) Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory. Magn Reson Med 48:297-305
Vigen, K K; Peters, D C; Grist, T M et al. (2000) Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging. Magn Reson Med 43:170-6
Barger, A V; Grist, T M; Block, W F et al. (2000) Single breath-hold 3D contrast-enhanced method for assessment of cardiac function. Magn Reson Med 44:821-4