X-ray fluoroscopy provides a combination of real-time imaging, high spatial resolution, ease of use, and device compatibility that is essential for rapid diagnosis of coronary artery disease and catheter guidance during fluoroscopically-guided interventional (FGI) procedures. Although the millions of FGI procedures performed in the U.S. each year undeniably improve and save lives, these procedures entail a radiation burden on both the patient and the medical staff who perform them. Radiation risks include serious skin injury, cataracts, and cancer. Unfortunately, there is limited room for improvement in the dose efficiency of conventional x-ray systems. The 2D projection format of conventional fluoroscopy also fails to provide the 3D device and anatomic information needed for modern catheter ablation procedures. The goal of this project is to develop a novel inverse-geometry x-ray fluoroscopic system that will dramatically reduce x-ray dose to patient and staff, while simultaneously providing real-time 3D catheter guidance. The Scanning-Beam Digital X-ray (SBDX) system is a low-dose fluoroscopic/fluorographic system that performs 30 frame/sec imaging using low-scatter inverse-geometry scanning. Previous NIH-funded research enabled the construction of an advanced SBDX system capable of reducing patient entrance skin dose to 15% of a conventional dose while maintaining 100% of conventional image signal-to-noise ratio. This research also yielded two new interventional techniques that exploit the unique SBDX real-time, multiplane, tomosynthetic reconstructor: frame-by-frame 3D catheter tip tracking and calibration-free 3D vessel analysis for device sizing. This new proposal will advance SBDX into the interventional laboratory through three projects. First, a human subjects study will be performed to compare SBDX and conventional x-ray dose, image quality, and interventional device sizing accuracy. Second, a procedure-room system for 3D catheter tracking and cardiac visualization will be constructed and validated in an animal model of ablation in the left atrium. Third, the ability to perform SBDX computed tomography in the interventional room will be developed, in order to provide 3D cardiac maps for ablation procedures without the need for a separate, pre-procedure CT scan. Reducing x-ray dose in the cardiac cath lab is critical to maximizing the safety of patient and staff. Real-time three-dimensional imaging capability is needed for many modern interventional procedures. The successful conclusion of this research will be a low dose x-ray fluoroscopic system which provides clinical image quality, novel therapeutic tools, and 3D imaging capability in a single interventional laboratory.

Public Health Relevance

Coronary artery disease and cardiac arrhythmia are significant causes of morbidity and mortality in our society. Over 1,000,000 coronary angioplasties and 200,000 catheter ablation procedures for the treatment of atrial fibrillation are performed annually in our country, saving many lives and improving the quality of many more. Successful completion of this work will provide therapeutic tools which improve the outcomes of these procedures, while dramatically lowering the radiation exposure to the patient and medical staff.

National Institute of Health (NIH)
National Heart, Lung, and Blood Institute (NHLBI)
Research Project (R01)
Project #
Application #
Study Section
Special Emphasis Panel (ZRG1-BMIT-J (01))
Program Officer
Buxton, Denis B
Project Start
Project End
Budget Start
Budget End
Support Year
Fiscal Year
Total Cost
Indirect Cost
University of Wisconsin Madison
Internal Medicine/Medicine
Schools of Medicine
United States
Zip Code
Tomkowiak, Michael T; Raval, Amish N; Van Lysel, Michael S et al. (2014) Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation. Proc SPIE Int Soc Opt Eng 9033:90332H
Tomkowiak, Michael T; Raval, Amish N; Van Lysel, Michael S et al. (2014) Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation. J Med Imaging (Bellingham) 1:
Burion, Steve; Speidel, Michael A; Funk, Tobias (2013) A real-time regional adaptive exposure method for saving dose-area product in x-ray fluoroscopy. Med Phys 40:051911
Speidel, Michael A; Wilfley, Brian P; Hsu, Annie et al. (2012) Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery. Med Phys 39:2163-9
Speidel, Michael A (2011) Inverse geometry x-ray imaging: application in interventional procedures. J Am Coll Radiol 8:74-7
Tomkowiak, Michael T; Speidel, Michael A; Raval, Amish N et al. (2011) Calibration-free device sizing using an inverse geometry x-ray system. Med Phys 38:283-93
McCabe, Bradley P; Speidel, Michael A; Pike, Tina L et al. (2011) Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner. Med Phys 38:1919-30