Sudden cardiac death (SCD) continues to pose a significant health care challenge with an annual incidence of over 350,000 and low survival rates. Implantable cardioverter defibrillators (ICDs) prevent SCD in patients with left ventricular (LV) systolic dysfunction. However, the critical survival benefit afforded by these devices is accompanied by short and long-term complications and a high economic burden. Moreover, in using current practice guidelines of LV ejection fraction (LVEF) d 35% as the main determining factor for patient selection, only a minority of patients actually benefit from ICD therapy (<25% in 5 years). There is an essential need for more robust diagnostic approaches to SCD risk stratification. This project examines the hypothesis that LV structural abnormalities are important independent predictors of SCD risk as they identify the presence and extent of the abnormal pathophysiologic substrate required for the ventricular arrhythmogenicity leading to SCD. This premise is supported by studies in pre-clinical models and limited patient cohorts examining the contribution of individual LV structural indices. However, there has been no prospective study of primary prevention ICD candidates in sufficiently large numbers to investigate the incremental value of a comprehensive, combined assessment of LV structure on SCD risk over and above that of LVEF and readily available demographic and clinical variables. We will utilize the largest, best characterized, current treatment era ICD patient population with a target study size of 400 patients and advanced cardiac magnetic resonance imaging to address this hypothesis. LV structure can be quantified in detail using cardiac magnetic resonance imaging with late gadolinium enhancement (CMR-LGE). Specifically, accurate assessment of LV volumes, mass, geometry, and infarct/scar characteristics, as well as global LV function, are feasible and obtainable clinically in a single examination.
We aim to examine whether or not a clinical risk score incorporating individual CMR indices or a combination of indices are better able to discriminate between patients with high versus low susceptibility to SCD within the broader population of reduced LVEF patients. If the results of these studies demonstrate that metrics of LV structure are important independent prognostic risk factors, it may then be possible to more specifically target ICD therapy to those who are most likely to benefit and avoid unnecessary device implantations and their associated morbidities and costs in those who do not have an arrhythmogenic LV structural phenotype.

Public Health Relevance

Sudden cardiac death (SCD) remains a significant health care dilemma with high incidence and low survival rates. While implantable cardioverter defibrillators (ICD) effectively prevent SCD, the process of selecting candidates for primary prevention therapy relies predominantly on a single criterion of reduced global LV function, which is a poorly sensitive index. There is a critical need for more robust diagnostic approaches and ones which focus on the heart's structural abnormalities may more specifically distinguish a truly high risk group who will benefit from the therapy from the low risk patients who are unnecessarily subjected to the risks and disadvantages of this high cost therapy.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
1R01HL103812-01
Application #
7944770
Study Section
Clinical and Integrative Cardiovascular Sciences Study Section (CICS)
Program Officer
Adhikari, Bishow B
Project Start
2010-07-15
Project End
2014-04-30
Budget Start
2010-07-15
Budget End
2011-04-30
Support Year
1
Fiscal Year
2010
Total Cost
$353,590
Indirect Cost
Name
Johns Hopkins University
Department
Internal Medicine/Medicine
Type
Schools of Medicine
DUNS #
001910777
City
Baltimore
State
MD
Country
United States
Zip Code
21218
Dhamala, Jwala; Arevalo, Hermenegild J; Sapp, John et al. (2018) Quantifying the uncertainty in model parameters using Gaussian process-based Markov chain Monte Carlo in cardiac electrophysiology. Med Image Anal 48:43-57
Tao, Susumu; Ciuffo, Luisa A; Lima, Joao A C et al. (2017) Quantifying left atrial structure and function using single-plane tissue-tracking cardiac magnetic resonance. Magn Reson Imaging 42:130-138
Tao, Susumu; Ashikaga, Hiroshi; Ciuffo, Luisa A et al. (2017) Impaired left atrial function predicts inappropriate shocks in primary prevention implantable cardioverter-defibrillator candidates. J Cardiovasc Electrophysiol 28:796-805
Dhamala, Jwala; Arevalo, Hermenegild J; Sapp, John et al. (2017) Spatially Adaptive Multi-Scale Optimization for Local Parameter Estimation in Cardiac Electrophysiology. IEEE Trans Med Imaging 36:1966-1978
Jablonowski, Robert; Chaudhry, Uzma; van der Pals, Jesper et al. (2017) Cardiovascular Magnetic Resonance to Predict Appropriate Implantable Cardioverter Defibrillator Therapy in Ischemic and Nonischemic Cardiomyopathy Patients Using Late Gadolinium Enhancement Border Zone: Comparison of Four Analysis Methods. Circ Cardiovasc Imaging 10:
Wu, Katherine C (2017) Sudden Cardiac Death Substrate Imaged by Magnetic Resonance Imaging: From Investigational Tool to Clinical Applications. Circ Cardiovasc Imaging 10:
Arevalo, Hermenegild J; Vadakkumpadan, Fijoy; Guallar, Eliseo et al. (2016) Arrhythmia risk stratification of patients after myocardial infarction using personalized heart models. Nat Commun 7:11437
Ukwatta, Eranga; Arevalo, Hermenegild; Li, Kristina et al. (2016) Myocardial Infarct Segmentation From Magnetic Resonance Images for Personalized Modeling of Cardiac Electrophysiology. IEEE Trans Med Imaging 35:1408-1419
Wu, Katherine C; Calkins, Hugh (2016) Powerlessness of a Number: Why Left Ventricular Ejection Fraction Matters Less for Sudden Cardiac Death Risk Assessment. Circ Cardiovasc Imaging 9:
Zhang, Yiyi; Guallar, Eliseo; Weiss, Robert G et al. (2016) Associations between scar characteristics by cardiac magnetic resonance and changes in left ventricular ejection fraction in primary prevention defibrillator recipients. Heart Rhythm 13:1661-6

Showing the most recent 10 out of 24 publications