Positron Emission Tomography Imaging of Thrombus The goal of this renewal proposal is to translate a recently developed fibrin-specific positron emission tomography (PET) probe, termed 64Cu-FBP8, for direct imaging of thrombus in patients. Thrombus plays a central role in a range of pathologies including ischemic stroke, myocardial infarction, pulmonary embolism, and deep vein thrombosis. The detection of thrombus with modern imaging techniques generally relies on the presence of filling defects, which are highly non-specific. Here we hypothesize that targeted molecular imaging of thrombus can be successfully performed in humans with a PET-detectable radiolabeled peptide. We further hypothesize that the accuracy of the probe will allow the presence/absence of thrombus in the left atrial appendage (LAA) to be imaged noninvasively. The current gold standard for the detection of LAA thrombus in patients with atrial fibrillation (AF) is transesophageal echo (TEE). While the experience with TEE is extensive, it is semi-invasive, requires sedation and prolonged monitoring, and does not prospectively identify patients with LAA thrombus before presentation to the hospital. A noninvasive alternative to TEE could improve patient comfort, streamline care, facilitate risk assessment in patients with AF and guide anti-coagulant management. This application, seeks to address this need through the clinical translation of 64Cu-FBP8for the detection of LAA thrombus in AF.
In Aim 1 we will assess the pharmacokinetics, distribution, and elimination of 64Cu-FBP8 in healthy volunteers to establish safety, radiochemical dose, and to estimate an optimal time for thrombus imaging.
In Aim 2 we will determine the accuracy of 64Cu-FBP8 PET to detect LAA thrombus in patients with AF, using recent TEE scans as the gold standard.
In Aim 3 we will prospectively image AF patients to establish the negative predicative value of 64Cu-FBP8 PET and its potential as a noninvasive alternative to TEE. To further the utility of 64Cu-FBP8 and to enable its use at other sites, in Aim 4 we will develop a sterile kit formulation that will make the widespread production of 64Cu-FBP8 feasible. The proposed research will translate a new molecular imaging agent into humans and lay the foundation for subsequent multicenter trials. The burden of AF is increasing rapidly and the noninvasive detection of LAA thrombosis is a large and unmet need. The proposed research is thus of major relevance to both clinical medicine and general population health.

Public Health Relevance

Thrombosis (blood clot) is implicated in a number of diseases such as stroke, heart attack, and pulmonary embolism. We have developed a new positron emitting imaging probe that directly targets thrombus. Here we will evaluate its ability to detect blood clots in the hearts of patients with atrial fibrillation.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL109448-06
Application #
9523217
Study Section
Clinical Molecular Imaging and Probe Development (CMIP)
Program Officer
Kindzelski, Andrei L
Project Start
2011-08-01
Project End
2021-05-31
Budget Start
2018-06-01
Budget End
2019-05-31
Support Year
6
Fiscal Year
2018
Total Cost
Indirect Cost
Name
Massachusetts General Hospital
Department
Type
DUNS #
073130411
City
Boston
State
MA
Country
United States
Zip Code
Boros, Eszter; Pinkhasov, Omar R; Caravan, Peter (2018) Metabolite profiling with HPLC-ICP-MS as a tool for in vivo characterization of imaging probes. EJNMMI Radiopharm Chem 3:2
Shea, Barry S; Probst, Clemens K; Brazee, Patricia L et al. (2017) Uncoupling of the profibrotic and hemostatic effects of thrombin in lung fibrosis. JCI Insight 2:
Oliveira, Bruno L; Caravan, Peter (2017) Peptide-based fibrin-targeting probes for thrombus imaging. Dalton Trans 46:14488-14508
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2015) Multisite Thrombus Imaging and Fibrin Content Estimation With a Single Whole-Body PET Scan in Rats. Arterioscler Thromb Vasc Biol 35:2114-21
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2015) Radiation Dosimetry of the Fibrin-Binding Probe ??Cu-FBP8 and Its Feasibility for PET Imaging of Deep Vein Thrombosis and Pulmonary Embolism in Rats. J Nucl Med 56:1088-93
Oliveira, Bruno L; Blasi, Francesco; Rietz, Tyson A et al. (2015) Multimodal Molecular Imaging Reveals High Target Uptake and Specificity of 111In- and 68Ga-Labeled Fibrin-Binding Probes for Thrombus Detection in Rats. J Nucl Med 56:1587-92
Loving, Galen S; Caravan, Peter (2014) Activation and retention: a magnetic resonance probe for the detection of acute thrombosis. Angew Chem Int Ed Engl 53:1140-3
Ay, Ilknur; Blasi, Francesco; Rietz, Tyson A et al. (2014) In vivo molecular imaging of thrombosis and thrombolysis using a fibrin-binding positron emission tomographic probe. Circ Cardiovasc Imaging 7:697-705
Boros, Eszter; Rybak-Akimova, Elena; Holland, Jason P et al. (2014) Pycup--a bifunctional, cage-like ligand for (64)Cu radiolabeling. Mol Pharm 11:617-29
Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A et al. (2014) Effect of Chelate Type and Radioisotope on the Imaging Efficacy of 4 Fibrin-Specific PET Probes. J Nucl Med 55:1157-63

Showing the most recent 10 out of 14 publications