The overall goal of this project is to develop an enhanced imaging technology using innovative convergent- beam collimation with 3D helical paths (HPs) for quantitative single photon emission computed tomography (SPECT). Promising SPECT molecular imaging agents are being developed for diagnosis of brain diseases such as Parkinson's disease. Full-cone-beam (FCB) SPECT has the potential to be an excellent diagnostic imaging tool for small brain structures, particularly those deep within the brain because of its magnification and its high detection efficiency, which increases with increasing proximity to the focal point. However, SPECT using a FCB collimator following a circular orbit has two limitations when applied to brain imaging: i) The source distribution is not completely sampled, which results in image artifacts for axial source locations that are not near the collimator's central, transaxial (perpendicular) focal plane; and ii) The caudal region of the brain cannot be imaged effectively because of interference of the patient's shoulders with the placement of the collimator. Even SPECT using a FCB collimator following a HP has the latter problem. Both problems are effectively addressed by the innovative combination of offset-astigmatic-beam (OAB) and spatially-variable-focusing (SVF) collimators following HPs: i) Complete spatial sampling can be obtained by using 3D HPs, resulting in high quality, artifact-free reconstructed images from projection data acquired at higher sensitivity and magnification; and ii) Shoulder interference is eliminated. OAB collimators can maintain close proximity to the brain and yet have their offset transaxial focal line positioned near the brain's caudal region. The proposed research will involve experimental scans, as well as computer simulations and analytic calculations. An existing triple-camera SPECT system and novel convergent-beam collimators, coupled with bed translation, will be used to demonstrate the innovative imaging technique. Iterative reconstruction software will be developed for helical-path OAB and SVF projection data. A laser alignment system and SPECT acquisitions of point sources will be used to determine parameters that describe system calibrations and mechanical and electrical misalignments of the SPECT scanner. Initially, uniformity of spatial sampling will be investigated using acquisitions that simulate two or three convergent-beam collimators versus the use of a single convergent-beam collimator. State-of-the-art reconstruction programs will account for the effects of system misalignments, point-spread-response, attenuation and scatter. The effects of these factors on image resolution, quantification and artifacts will be evaluated using a selection of geometric and anthropomorphic phantoms. A pilot clinical study will involve a small number of human subjects. This proposal supports the research and development of new imaging techniques, and the results will provide data upon which significant translational research can be built. In the long term, the new techniques will potentially provide better health care through improved diagnosis of brain disease. ? ? ?

Agency
National Institute of Health (NIH)
Institute
National Institute of Neurological Disorders and Stroke (NINDS)
Type
Research Project (R01)
Project #
5R01NS054797-02
Application #
7216195
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Chen, Daofen
Project Start
2006-04-01
Project End
2009-03-31
Budget Start
2007-04-01
Budget End
2008-03-31
Support Year
2
Fiscal Year
2007
Total Cost
$261,208
Indirect Cost
Name
Duke University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
044387793
City
Durham
State
NC
Country
United States
Zip Code
27705
Ter-Antonyan, Ruben; Jaszczak, Ronald J; Greer, Kim L et al. (2009) Combination of converging collimators for high-sensitivity brain SPECT. J Nucl Med 50:1548-56
Ter-Antonyan, Ruben; Jaszczak, Ronald J; Bowsher, James E et al. (2008) Quantitative Evaluation of Half-Cone-Beam Scan Paths in Triple-Camera Brain SPECT. IEEE Trans Nucl Sci 55:2518-2526
Ter-Antonyan, Ruben; Jaszczak, Ronald J; Bowsher, James E et al. (2007) Brain SPECT Simulation Using Half-Cone-Beam Collimation and Single-Revolution Helical-Path Acquisition. IEEE Trans Nucl Sci 54:475-479