Measurement of transcutaneous oxygen perfusion through the skin is used clinically as a measure of blood flow to a region of the body, and serves as an indicative measure of wound healing potential. Topical oximetry may also be useful for tracking peripheral vascular disease (PVD). Currently, the only clinically-applied technique used for this purpose is transcutaneous oxygen monitoring (TCOM) using electrode based sensors, which require an active heating element to encourage diffusion of oxygen through the skin. Subcutaneous (2 - 3 mm below the skin surface) tissue oxygen measurements would be useful in determining blood flow in vascularized free tissue flaps used for reconstructive surgery or in tissues surrounding chronic wounds. Our group has demonstrated that biopolymer-encapsulated probes used in electron paramagnetic resonance (EPR) oximetry can be used for such applications when applied topically to the region of interest, or implanted below the skin. The use of EPR for such measurements is currently not feasible in a clinical setting due to the size, weight, and space restrictions presented by existing instrumentation. We therefore propose to design, build, and test a new, portable EPR system for clinical oximetry applications. The envisioned device will be similar to a clinical ultrasound unit, with a """"""""wand"""""""" assembly that will be placed in contact with the skin to obtain oximetry measurements from the probe sensors placed on the body, or implanted just below the surface. We will use computer modeling to determine the optimum arrangement of magnets and resonator prior to construction of a working prototype device. We will then test and characterize the oxygen-sensitive probes to be used. We will then use the prototype device to quantify tissue oxygenation in a rat chronic wound model, and continue with validation measurements using the portable EPR unit on human volunteers to compare this new technology with the existing electrode-based TCOM.

Public Health Relevance

Diffusion of oxygen through the surface of the skin (transcutaneous oxygen diffusion) can be used as a diagnostic tool for a number of different diseases and conditions, including peripheral vascular disease (PVD). Subcutaneous tissue oxygen levels can be used as an indicator of wound healing potential or tissue graft transplant success. The objective of this proposal is to design and construct a new device which will permit accurate and rapid quantification of transcutaneous oxygen perfusion and subcutaneous (2 - 3 mm below the skin) oxygen levels in clinical settings.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
7R21EB016189-02
Application #
8535154
Study Section
Special Emphasis Panel (ZRR1-BT-7 (01))
Program Officer
Sastre, Antonio
Project Start
2012-09-01
Project End
2015-08-31
Budget Start
2013-09-01
Budget End
2014-08-31
Support Year
2
Fiscal Year
2013
Total Cost
$185,206
Indirect Cost
$64,313
Name
Dartmouth College
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
041027822
City
Hanover
State
NH
Country
United States
Zip Code
03755