The goal of this small business innovation research grant is to develop and commercialize a cost-effective, contrast-assisted intraoperative ureter detection system, which integrates into existing surgical tools to identify ureters in real-time and prevent iatrogenic injuries. 70% of iatrogenic ureteral injuries are detected postoperatively, up to 30 days after hospital discharge. These injuries can cause ureteral obstruction, fistula(e) and eventually renal failure when not repaired immediately, and cost hospitals an average of $30,000 per patient with an added hospitalization time of 4 days. Currently, the only available technologies that assist in ureter detection, including cystoscopy and lighted stents, are costly and have led to additional complications such as reflux anuria and urinary tract infections. The RUD system would be the first unobtrusive and cost-effective alternative with the potential to decrease the incidence of ureteral complications during surgery. In this SBIR project, Briteseed will continue the development of a ureter detection system, and validate its capabilities in both ex vivo and in vivo porcine studies. This rapid ureter detection (RUD) system will use optical technology to non-invasively detect the ureters in real-time and prevent iatrogenic injury during surgery. This system will enable users to detect the ureters using methylene blue (MB), an FDA-approved and clinically utilized dye, as a contrast agent during surgery. No additional tools such as catheters, stents and cystoscopy will be used, therefore avoiding any complications caused by these tools. By preventing ureteral injury through real- time detection, this technology will lead to safer surgical outcomes for patients and lessen the financial burden on hospitals. In Phase I of the SBIR, the RUD system will be optimized and validated to provide: (a) real-time, automated ureter detection and (b) ability to differentiate between the ureter and surrounding tissues. In Phase II, the RUD system will be modified to integrate into surgical tools most commonly used near the ureters during gynecological procedures (i.e. thermal ligature devices, grasper/dissectors). This technology will profoundly affect gynecological procedures, where the ureter is at high risk with no highly adopted detection method currently available to prevent injury.

Public Health Relevance

Studies have shown that 70% of iatrogenic ureteral injuries are detected postoperatively, up to 30 days after hospital discharge. These injuries can cause ureteral obstruction, fistula(e) and eventually renal failure when not repaired immediately, and cost hospitals an average of $30,000 per patient with an added hospitalization time of 4 days. Currently, the only available technologies that assist in ureter detection, including cystoscopy and lighted stents, are costly and have led to additional complications such as reflux anuria and urinary tract infections. This SBIR project aims to develop and commercialize the Rapid Ureter Detection (RUD) system which would be the first unobtrusive and cost-effective alternative with the potential to decrease the incidence of ureteral complications during surgery.

Agency
National Institute of Health (NIH)
Institute
Eunice Kennedy Shriver National Institute of Child Health & Human Development (NICHD)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43HD089769-01
Application #
9202396
Study Section
Special Emphasis Panel (ZRG1)
Program Officer
Tingen, Candace M
Project Start
2016-08-01
Project End
2017-04-01
Budget Start
2016-08-01
Budget End
2017-04-01
Support Year
1
Fiscal Year
2016
Total Cost
Indirect Cost
Name
Briteseed, LLC
Department
Type
DUNS #
078742429
City
Chicago
State
IL
Country
United States
Zip Code
60611