Current pre-operative and intraoperative margin assessment techniques fail to adequately guide breast cancer surgeons to remove all cancer during breast conserving surgeries. As a result, more than 30% of lumpectomy patients have unrecognized tumor left in the tumor bed during the initial surgery. This residual tumor is only discovered when the pathologist evaluates the resection margins one week later and finds a positive margin. The majority of patients with positive margins (~87%) require a second surgery, which increases health care costs along with patient anxiety and discomfort. To address this unmet need, Lumicell has developed an intraoperative imaging system consisting of a molecular imaging agent (LUM015) that emits fluorescence after activation by cancer associated enzymes, a compact hand-held imaging head (LUM 2.6 Device) that captures the fluorescence emission of the agent and software that detects and displays invasive carcinomas (80% of the breast cancer cases) in real-time to guide the surgeon. Our collaborators at the Massachusetts General Hospital are conducting a feasibility study in breast cancer patients under an FDA-approved IDE. The first part of the feasibility study has been completed with no adverse events observed in 15 patients. Initial results from the feasibility study show no false negatives (100% sensitivity) with ~10% false positives. During this study, Lumicell developed an approach for detecting the much smaller foci of ductal carcinoma in situ (DCIS; 20% of breast cancer cases). As the first aim of this proposal, we will develop and implement software for real- time detection of DCIS. Our next proposed aim is a two arm, multi-institution pivotal clinical trial in support of our PMA application to measure the efficacy of the LUM Imaging System. The primary endpoint of the study is the reduction in positives margin rates for surgeries in which the LUM Imaging System is used versus standard of care (SOC) treatment for breast cancer patients undergoing breast conserving lumpectomies. The secondary endpoint is a reduction in the rate of second surgeries due to positive margins when the LUM Imaging System is used. The device arm will consists of 300 patients, while the control (SOC) arm will consists of 100 patients. In the SOC arm, patients will undergo a routine lumpectomy procedure. In the device arm, patients will undergo SOC treatment followed by imaging of the lumpectomy cavity with the LUM Imaging System. Additional therapeutic cavity shaves will be removed from regions that Lumicell's detection algorithm determines to contain cancer.

Public Health Relevance

The proposed project aims to address the unmet clinical need for intraoperative assessment and removal of residual cancer cells in the lumpectomy cavity after gross tumor resection in breast cancer patients. A novel imaging method for fast and thorough imaging of the tumor bed in real-time will be tested in a pivotal clinical study to measure efficacy in reducing positive margin rates and eliminating the need for repeat surgeries. Successful completion of this project will enable the FDA approval required to put this technology in the hands of breast cancer surgeons, improving care for breast cancer patients.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
1R44CA211013-01
Application #
9200487
Study Section
Special Emphasis Panel (ZRG1-SBIB-T (10)B)
Program Officer
Narayanan, Deepa
Project Start
2016-07-04
Project End
2018-06-30
Budget Start
2016-07-04
Budget End
2017-06-30
Support Year
1
Fiscal Year
2016
Total Cost
$1,033,123
Indirect Cost
Name
Lumicell Diagnostics, Inc.
Department
Type
DUNS #
832329788
City
Wellesley
State
MA
Country
United States
Zip Code
02481