Glaucoma, a widespread, chronic disease, is a leading cause of blindness and is related to the death of retinal ganglionic cells. In the most prevalent form of glaucoma, primary open-angle glaucoma (POAG), increased intraocular pressure (IOP) is the most common risk factor associated with the loss of retinal cells. Results from large clinical trials indicate that decreasing IOP in glaucoma patients delays the development of vision loss. Even glaucoma patients with IOPs in the normal range benefit from decreasing their IOP. Currently, numerous pharmacological and surgical approaches are employed to reduce IOP in glaucoma patients. However, drug treated patients are frequently noncompliant, refractory and/or suffer from adverse effects. Current surgical implants are passive devices unable to detect or respond to changes in IOP and frequently fail. With either approach, a patient office visit is required for the physician to manually verify IOP control by tonometry. We propose to create an implant capable of both sensing IOP and regulating it through opening and closing a miniature valve. The implant's power supply will be self-contained, with a transceiver capable of sending and receiving external commands. In its final form the implant will monitor and regulate IOP and be capable of recording and sending IOP data and information concerning valve function to the physician and/or patient via a digital device such as a PC. The three specific, measurable objectives for Phase II are to: 1) Design and fabricate a miniature twin magnetic stop/electromagnetic valve with accompanying telemetry and data acquisition system. 2) Perform short and long-term in vitro tests of the valve to demonstrate detection, response and control of IOP in the normal and pathological pressure ranges. 3) Implant the valve and test it both acutely and chronically on conscious, active normal IOP rabbits to determine safety and efficacy.

Public Health Relevance

Glaucoma, a wide spread ocular disease, is associated with pressure increases inside the eye and, if left untreated, causes blindness. We will create an electronically controlled valve and pressure recorder to be placed in the eye that will reduce this pressure and preserve sight, as well as continually inform the physician of the eye pressure and proper functioning of the valve.

Agency
National Institute of Health (NIH)
Institute
National Eye Institute (NEI)
Type
Small Business Innovation Research Grants (SBIR) - Phase II (R44)
Project #
2R44EY014284-02A1
Application #
8707806
Study Section
Special Emphasis Panel (ZRG1-ETTN-G (12))
Program Officer
Wujek, Jerome R
Project Start
2002-07-01
Project End
2016-04-30
Budget Start
2014-05-01
Budget End
2015-04-30
Support Year
2
Fiscal Year
2014
Total Cost
$966,681
Indirect Cost
Name
Forsythe Technologies Worldwide, Inc.
Department
Type
DUNS #
148633683
City
Woodland Hills
State
CA
Country
United States
Zip Code
91367