Project 3: Carbon Nanotube X-Ray for in-vivo Cancer Detection X-rays are indispensable in many medical applications including cancer detection, characterization and treatment. The basic design of the x-ray tube however has not changed significantly: a thermionic cathode is used to produce electrons which strike on a metal target to generate x-ray. It has several intrinsic drawbacks that have limited the effectiveness and advancements of the x-ray technologies. These include high cathode operating temperature (~1000?C) which prevents miniaturization and novel source configurations that can increase imaging speed and accuracy, high imaging dose which causes radiation damage, and low temporal and spatial resolution which affects the size and accuracy of the features can be detected. Carbon nanotube (CNT) based field emission x-ray sources have the potential to not only overcome these limitations but also enable new novel imaging modalities. Preliminary results from our group have demonstrated that the CNT x-ray technology: (1) can generate programmable pulsed x-ray waveform with high temporal resolution which readily enables synchronized/gated imaging and temporal Fourier processing to increase signal/noise ratio;(2) allows novel source configurations such as scanning multi-beam x-ray sources for dynamic and high-speed tomographic imaging;(3) miniaturizes x-ray sources with the possibility of """"""""x-ray on chip"""""""" technologies. Specific CNT x-ray technologies for cancer imaging and radiotherapy for humans and animal model research will be developed. It will be carried out in three phases including technology development, evaluation, and transition into clinical use. Phase 1 concentrates on the development of: (1) CNT field emission x-ray sources, in particular multi-beam field emission x-ray (MBFEX) sources that can generate spatial-temporal programmable scanning x-ray without mechanical motion;(2) temporal Fourier digital radiography (TFDR) method for low-dose and high-speed imaging;(3) stationary ultrafast micro-computed tomography (micro-CT) scanner for dynamic small animal imaging;(4) stationary tomosynthesis and CT systems for imaging of human breast cancer;and (5) a novel micro- RT (radiotherapy) system that can be combined with micro-CT for guided conformal radiotherapy for cancer research on small animal models. In Phase 2 these new technologies will be evaluated using phantoms and animal models and will be utilized to investigate lung and colon cancers in specific mouse models developed at UNC. In Phase 3, fully functional and user-friendly prototypes will be constructed for clinical and animal model research use

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Specialized Center--Cooperative Agreements (U54)
Project #
5U54CA119343-05
Application #
7934026
Study Section
Special Emphasis Panel (ZCA1)
Project Start
Project End
Budget Start
2009-09-01
Budget End
2010-08-31
Support Year
5
Fiscal Year
2009
Total Cost
$595,560
Indirect Cost
Name
University of North Carolina Chapel Hill
Department
Type
DUNS #
608195277
City
Chapel Hill
State
NC
Country
United States
Zip Code
27599
Bowerman, Charles J; Byrne, James D; Chu, Kevin S et al. (2017) Docetaxel-Loaded PLGA Nanoparticles Improve Efficacy in Taxane-Resistant Triple-Negative Breast Cancer. Nano Lett 17:242-248
Koh, Ai Leen; Gidcumb, Emily; Zhou, Otto et al. (2016) Oxidation of Carbon Nanotubes in an Ionizing Environment. Nano Lett 16:856-63
Giovinazzo, Hugh; Kumar, Parag; Sheikh, Arif et al. (2016) Technetium Tc 99m sulfur colloid phenotypic probe for the pharmacokinetics and pharmacodynamics of PEGylated liposomal doxorubicin in women with ovarian cancer. Cancer Chemother Pharmacol 77:565-73
Burk, Laurel M; Wang, Ko-Han; Wait, John Matthew et al. (2015) Delayed contrast enhancement imaging of a murine model for ischemia reperfusion with carbon nanotube micro-CT. PLoS One 10:e0115607
Chu, Kevin S; Finniss, Mathew C; Schorzman, Allison N et al. (2014) Particle replication in nonwetting templates nanoparticles with tumor selective alkyl silyl ether docetaxel prodrug reduces toxicity. Nano Lett 14:1472-6
Chhetri, Raghav K; Blackmon, Richard L; Wu, Wei-Chen et al. (2014) Probing biological nanotopology via diffusion of weakly constrained plasmonic nanorods with optical coherence tomography. Proc Natl Acad Sci U S A 111:E4289-97
Song, Gina; Petschauer, Jennifer S; Madden, Andrew J et al. (2014) Nanoparticles and the mononuclear phagocyte system: pharmacokinetics and applications for inflammatory diseases. Curr Rheumatol Rev 10:22-34
Tucker, Andrew W; Lu, Jianping; Zhou, Otto (2013) Dependency of image quality on system configuration parameters in a stationary digital breast tomosynthesis system. Med Phys 40:031917
Oldenburg, Amy L; Chhetri, Raghav K; Cooper, Jason M et al. (2013) Motility-, autocorrelation-, and polarization-sensitive optical coherence tomography discriminates cells and gold nanorods within 3D tissue cultures. Opt Lett 38:2923-6
Koh, Ai Leen; Gidcumb, Emily; Zhou, Otto et al. (2013) Observations of carbon nanotube oxidation in an aberration-corrected environmental transmission electron microscope. ACS Nano 7:2566-72

Showing the most recent 10 out of 92 publications