We have developed and validated a series of quantitative perfusion methods including a dual bolus protocol (Christian TF et al. Radiology. 2004;232(3):677-84). We demonstrated that all of the conclusions from the pre-clinical studies were applicable and relevant in people (Hsu L et al. J Magn Reson Imaging 2006;23(3):315-22). One problem common to prior quantitative perfusion analyses (including our own work) has been reliance on region of interest analysis or sector-based analysis. These types of sector-based analyses are equivalent to degrading the image resolution by a factor of 10-50 and result in rather blocky representations of myocardial perfusion. Since physicians generally interpret perfusion images by watching a series of images played in a digital video loop at full resolution, we hypothesized that MRI could evaluate fully quantitative myocardial blood flow (MBF) at a pixel level based on contrast-enhanced first-pass cardiac magnetic resonance (CMR) imaging in dogs and patients. We found that myocardial blood flow could be quantified at the pixel level (32 microliters of myocardium) on CMR perfusion images and results compared well with microsphere measurements (Hsu L et al. in press). Furthermore, high-resolution pixel-wise CMR perfusion maps could detect transmural perfusion gradients. These methods may improve the objectivity of diagnosing CAD in patients.

Project Start
Project End
Budget Start
Budget End
Support Year
2
Fiscal Year
2012
Total Cost
$1,162,910
Indirect Cost
Name
National Heart, Lung, and Blood Institute
Department
Type
DUNS #
City
State
Country
Zip Code
Jacobs, Matthew; Benovoy, Mitchel; Chang, Lin-Ching et al. (2016) Evaluation of an automated method for arterial input function detection for first-pass myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 18:17
Nguyen, Kim-Lien; Tian, Xin; Alam, Shoaib et al. (2016) Elevated transpulmonary gradient and cardiac magnetic resonance-derived right ventricular remodeling predict poor outcomes in sickle cell disease. Haematologica 101:e40-3
Kühl, Jørgen Tobias; George, Richard T; Mehra, Vishal C et al. (2015) Endocardial-epicardial distribution of myocardial perfusion reserve assessed by multidetector computed tomography in symptomatic patients without significant coronary artery disease: insights from the CORE320 multicentre study. Eur Heart J Cardiovasc Imaging :
Miller, Christopher A; Hsu, Li-Yueh; Ta, Allison et al. (2015) Quantitative pixel-wise measurement of myocardial blood flow: the impact of surface coil-related field inhomogeneity and a comparison of methods for its correction. J Cardiovasc Magn Reson 17:11
van der Pals, Jesper; Hammer-Hansen, Sophia; Nielles-Vallespin, Sonia et al. (2015) Temporal and spatial characteristics of the area at risk investigated using computed tomography and T1-weighted magnetic resonance imaging. Eur Heart J Cardiovasc Imaging :
Nielles-Vallespin, Sonia; Kellman, Peter; Hsu, Li-Yueh et al. (2015) FLASH proton density imaging for improved surface coil intensity correction in quantitative and semi-quantitative SSFP perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 17:16
Ismail, Tevfik F; Hsu, Li-Yueh; Greve, Anders M et al. (2014) Coronary microvascular ischemia in hypertrophic cardiomyopathy - a pixel-wise quantitative cardiovascular magnetic resonance perfusion study. J Cardiovasc Magn Reson 16:49
Shaw, Leslee J; Berman, Daniel S; Picard, Michael H et al. (2014) Comparative definitions for moderate-severe ischemia in stress nuclear, echocardiography, and magnetic resonance imaging. JACC Cardiovasc Imaging 7:593-604
Chen, Marcus Y; Bandettini, W Patricia; Shanbhag, Sujata M et al. (2014) Concordance and diagnostic accuracy of vasodilator stress cardiac MRI and 320-detector row coronary CTA. Int J Cardiovasc Imaging 30:109-19
Nguyen, Kim-Lien; Bandettini, W Patricia; Shanbhag, Sujata et al. (2014) Safety and tolerability of regadenoson CMR. Eur Heart J Cardiovasc Imaging 15:753-60

Showing the most recent 10 out of 16 publications