In recent years we have successfully developed many methods to overcome problems associated with static and radiofrequency (RF) magnetic field distortions inherent with high field human MRI, but many challenges still remain. For this renewal we propose to 1) determine optimal configurations of practical transmit RF arrays and pulsing methods for safe, versatile, homogeneous RF excitation in the head and body at several key field strengths, 2) develop a reliable, real-time method of ensuring RF safety in transmit arrays, where currently an infinite number of power absorption patterns are possible for a given array and subject and little is known about the safety implications, and 3) implement and demonstrate key progressive transmit arrays and pulsing methods for body and head imaging at a few key field strengths, along with a reliable RF array safety monitoring system. To accomplish these Aims we will continue the partnership between the Pennsylvania State University (PSU: Lead Investigator CM Collins), the University of Minnesota (UMN: Lead Investigators K Ugurbil and JT Vaughan), and Remcom, Inc. (Lead Investigator R Luebbers). The partnership will be led by PSU. The approach will be multidisciplinary in that it will require 1) numerical simulations of a) RF fields (PSU, Remcom) b) nuclear magnetic phenomena (PSU), and c) temperature and related physiology (PSU, Remcom) to guide development of RF hardware and pulses and the safety monitoring system, 2) RF hardware design and implementation (PSU, UMN), and 3) high field MRI experiments (PSU, UMN). With this project we will make significant improvements to Magnetic Resonance Imaging (MRI) Technology. We will develop, implement, and demonstrate technology to make MRI safer, faster, and more effective for all research and, eventually, medical applications.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB000454-09
Application #
8051698
Study Section
Special Emphasis Panel (ZRG1-SBIB-V (50))
Program Officer
Liu, Guoying
Project Start
2002-09-30
Project End
2011-12-31
Budget Start
2011-04-01
Budget End
2011-12-31
Support Year
9
Fiscal Year
2011
Total Cost
$834,211
Indirect Cost
Name
Pennsylvania State University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
129348186
City
Hershey
State
PA
Country
United States
Zip Code
17033
Meadowcroft, Mark D; Wang, Jianli; Purnell, Carson J et al. (2018) Reduced Cerebral White Matter Integrity Assessed by DTI in Cognitively Normal H63D-HFE Polymorphism Carriers. J Neuroimaging 28:126-133
Meadowcroft, Mark D; Wang, Jianli; Purnell, Carson J et al. (2016) Reduced white matter MRI transverse relaxation rate in cognitively normal H63D-HFE human carriers and H67D-HFE mice. Brain Imaging Behav 10:1231-1242
Martin, John T; Collins, Christopher M; Ikuta, Kensuke et al. (2015) Population average T2 MRI maps reveal quantitative regional transformations in the degenerating rabbit intervertebral disc that vary by lumbar level. J Orthop Res 33:140-8
Xin, Sherman Xuegang; Gu, Shiyong; Carluccio, Giuseppe et al. (2015) Consideration of the effects of intense tissue heating on the RF electromagnetic fields during MRI: simulations for MRgFUS in the hip. Phys Med Biol 60:301-7
Cao, Zhipeng; Park, Joshua; Cho, Zang-Hee et al. (2015) Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit/receive array. J Magn Reson Imaging 41:1432-9
Meadowcroft, Mark D; Peters, Douglas G; Dewal, Rahul P et al. (2015) The effect of iron in MRI and transverse relaxation of amyloid-beta plaques in Alzheimer's disease. NMR Biomed 28:297-305
Cao, Zhipeng; Oh, Sukhoon; Otazo, Ricardo et al. (2015) Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI-induced RF heating. Magn Reson Med 73:1420-31
Cao, Zhipeng; Oh, Sukhoon; Sica, Christopher T et al. (2014) Bloch-based MRI system simulator considering realistic electromagnetic fields for calculation of signal, noise, and specific absorption rate. Magn Reson Med 72:237-47
Oh, Sukhoon; Ryu, Yeun-Chul; Carluccio, Giuseppe et al. (2014) Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation. Magn Reson Med 71:1923-31
Carluccio, Giuseppe; Collins, Christopher M; Erricolo, Danilo (2014) A fast, analytically based method to optimize local transmit efficiency for a transmit array. Magn Reson Med 71:432-9

Showing the most recent 10 out of 49 publications