The Atomic Force Microscope (AFM) can image and manipulate biological samples under physiological conditions at nanometer resolution. Despite its very slow operation (sometimes over 30 minutes per image) and the special expertise required to overcome its complexity of use, the AFM has already facilitated significant biomedical discoveries including new insights into membrane proteins and the mechanical properties of structural proteins. The range of biological processes the AFM can image is, however, severely limited by the AFM's current low time resolution, which is due to fundamental limits inherent in the current generation of AFMs based on cantilevers with dimensions of order 100 microns. This new generation of user-friendly (2 hours' training), high speed (2 images/second) AFMs is proposed to be developed based on fundamental innovations in design, particularly by basing the new AFMs on cantilevers with dimensions of order 10 microns to improve time and force resolution for probing molecules and speed in imaging by an order of magnitude or more.
The Specific Aims of the project are: i) to develop a high-speed AFM that can image at 512x512 resolution, at 2 images/second; 2) to develop a user-friendly AFM in which most of the processes in setting up the AFM and adjusting feedback parameters are automated; 3) to develop a new AFM that combines high-speed with automation. It is hoped and expected that these new AFMs can serve as prototypes to guide the development of future commercial AFMs, which can bring the advantages of high-speed and automation to the broader community of biomedical researchers. This new generation of AFMs will be fast and easy to use and have improved tune and force resolution. This will facilitate imaging of biological processes at the molecular level and thus have a broad enabling impact on biomedical research. The long term goal is to transition the AFM from a specialized research tool to a general use medical instrument. ? ? ?
Lescun, Timothy B; Hoffseth, Kevin; Yang, Henry T et al. (2016) Effect of various testing conditions on results for a handheld reference point indentation instrument in horses. Am J Vet Res 77:39-49 |
Drake, Barney; Randall, Connor; Bridges, Daniel et al. (2014) A new ion sensing deep atomic force microscope. Rev Sci Instrum 85:083706 |
Farr, Joshua N; Drake, Matthew T; Amin, Shreyasee et al. (2014) In vivo assessment of bone quality in postmenopausal women with type 2 diabetes. J Bone Miner Res 29:787-95 |
Szabo, M E; Thurner, P J (2013) Anisotropy of bovine cortical bone tissue damage properties. J Biomech 46:2-6 |
Randall, Connor; Bridges, Daniel; Guerri, Roberto et al. (2013) Applications of a New Handheld Reference Point Indentation Instrument Measuring Bone Material Strength. J Med Device 7:410051-410056 |
Guerri-Fernandez, Roberto C; Nogues, Xavier; Quesada Gomez, Jose M et al. (2013) Microindentation for in vivo measurement of bone tissue material properties in atypical femoral fracture patients and controls. J Bone Miner Res 28:162-8 |
Barnard, H; Drake, B; Randall, C et al. (2013) Deep atomic force microscopy. Rev Sci Instrum 84:123701 |
Bridges, Daniel; Randall, Connor; Hansma, Paul K (2012) A new device for performing reference point indentation without a reference probe. Rev Sci Instrum 83:044301 |
Barnard, H; Randall, C; Bridges, D et al. (2012) The long range voice coil atomic force microscope. Rev Sci Instrum 83:023705 |
Szabó, M E; Zekonyte, J; Katsamenis, O L et al. (2011) Similar damage initiation but different failure behavior in trabecular and cortical bone tissue. J Mech Behav Biomed Mater 4:1787-96 |
Showing the most recent 10 out of 45 publications