Estimates of the hip joint centers (HJC) are usually based on predictions from anatomical landmarks and anthropometrical measures such as pelvic breadth. There is concern regarding the relevance of this approach in patients characterized by obesity or pelvic deformity. Recent investigations have explored estimating HJCs using the functional method. Current literature often fails to disclose the form of the algorithm used in these tests, although three distinct forms exist. In addition, previous research has ignored the interaction between the algorithms, the portion of sphere surface represented by the data, the nature and magnitude of noise contained in the data, and the effect of different marker placement strategies. The goal of this project is to understand these interactions in order to know when clinical implementation of the functional method is appropriate and when it is likely to produce erroneous results.
The specific aims of his project are: 1) to model the area of motion and radial perturbation values as a function of the error associated with the functional algorithms, 2) to determine the effect of area of motion on HJC estimates measured under non weight-bearing conditions, 3) to determine the effect of marker placement on radial perturbations and HJC estimates under non weight-bearing conditions, 4) to compare the functional algorithms to estimates from prediction methods and with known HJC locations based on ultrasound and DEXA imaging, and 5) to determine the characteristics of functional algorithms and marker placement strategies on HJC estimates measured during weight-bearing. In the computer modeling component of this study, the range of hip flex/ext, abd/add, and random radial noise will be systematically altered in order to produce maps of the centroid displacement. The maps calculated from these simulations will be used to establish theoretical constraints for use of the algorithms in clinic. In the clinical component of the study, the standard for HJC location will be determined with DEXA and ultrasound. Motion analysis data collected during standing and walking trials will be used to reconstruct HJCs from 1) different algorithms, 2) different virtual knee marker reconstruction methods, and 3) delimited amounts of sphere surface. The characteristics of marker noise associated with different placement strategies will be analyzed. Resulting HJCs will be compared to the standard to determine the interactions of each variable, and the acceptable range of values from each variable that will produce HJCs within 1 cm of the standard.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Small Business Innovation Research Grants (SBIR) - Phase I (R43)
Project #
1R43CA103563-01
Application #
6694637
Study Section
Special Emphasis Panel (ZRG1-SSS-7 (11))
Program Officer
Baker, Houston
Project Start
2003-09-01
Project End
2004-08-31
Budget Start
2003-09-01
Budget End
2004-08-31
Support Year
1
Fiscal Year
2003
Total Cost
$149,800
Indirect Cost
Name
Anticancer, Inc.
Department
Type
DUNS #
173844010
City
San Diego
State
CA
Country
United States
Zip Code
92111
Hoffman, Robert M (2014) Imaging metastatic cell trafficking at the cellular level in vivo with fluorescent proteins. Methods Mol Biol 1070:171-9
Bouvet, Michael; Hoffman, Robert M (2012) In vivo imaging of pancreatic cancer with fluorescent proteins in mouse models. Methods Mol Biol 872:51-67
Hoffman, Robert M (2011) Nestin-driven green fluorescent protein as an imaging marker for nascent blood vessels in mouse models of cancer. Methods Mol Biol 689:183-204
Tran Cao, Hop S; Kaushal, Sharmeela; Lee, Claudia et al. (2011) Fluorescence laparoscopy imaging of pancreatic tumor progression in an orthotopic mouse model. Surg Endosc 25:48-54
Zhang, Qingbei; Yang, Meng; Shen, Jikun et al. (2010) The role of the intravascular microenvironment in spontaneous metastasis development. Int J Cancer 126:2534-41
Yang, Meng; Reynoso, Jose; Bouvet, Michael et al. (2009) A transgenic red fluorescent protein-expressing nude mouse for color-coded imaging of the tumor microenvironment. J Cell Biochem 106:279-84
Bouvet, M; Hoffman, R M (2009) Clinically-relevent orthotopic metastatic models of pancreatic cancer imageable with fluorescent genetic reporters. Minerva Chir 64:521-39
Cao, Hop S Tran; Kimura, Hiroaki; Kaushal, Sharmeela et al. (2009) The cyan fluorescent protein (CFP) transgenic mouse as a model for imaging pancreatic exocrine cells. JOP 10:152-6
Andresen, Volker; Alexander, Stephanie; Heupel, Wolfgang-Moritz et al. (2009) Infrared multiphoton microscopy: subcellular-resolved deep tissue imaging. Curr Opin Biotechnol 20:54-62
Makale, Milan; McElroy, Michele; O'Brien, Peter et al. (2009) Extended-working-distance multiphoton micromanipulation microscope for deep-penetration imaging in live mice and tissue. J Biomed Opt 14:024032

Showing the most recent 10 out of 20 publications