Asthma is a progressive inflammatory disease of the lungs that leads to structural airway changes and debilitating symptoms in many affected children and adults. It is the most common chronic childhood disease, and asthma attacks are the most common reason children miss school. More than 5 million children have asthma and the prevalence of asthma in some inner cities in the United States is greater than 20%. While environmental triggers are recognized as key parameters in managing pediatric asthma, it has been challenging to concurrently measure health metrics in children at the same time as quantifying the triggers to which they are being exposed. A technology gap has existed for portable monitoring systems that can perform these functions simultaneously while continuously logging data. This project will develop a safe and effective wearable diagnostic health monitoring sensor for children with asthma to improve their daily quality of life. It will combine four major functions in a single packaged system worn by the user: (1) routine portable spirometry and pulmonary lung function measurements can be taken and logged by the user on-demand; (2) exhaled breath oxylipin biomarkers can be measured and logged in near-real-time by the user on-demand; (3) environmental chemical monitoring will be continuously logged to understand background triggers of asthma; (4) patient symptoms and drug use will be manually logged by the user enabled by an intuitive graphical user interface. In a prior pediatric asthma clinical trial using breath monitoring, we found that eicosanoids were measureable in exhaled breath and were consistent with the levels needed for detection using the novel and portable instruments we have developed. For this period, we aim: 1) To establish a wearable sensor system architecture integrating our modular components into a total breath monitoring system capable of: spirometry, real-time eicosanoid measurements, and continuous environmental chemical monitoring, and 2) To enroll 10 adolescent asthmatic subjects to use the new wearable sensor in a longitudinal pilot clinical trial over 8 months to test the hypothesis that increased breath eicosanoid levels correlate with increased asthma symptoms and worse lung function. At the end of this study, we anticipate our prototype system will have been benchmarked for use specifically in pediatric asthma metabolite monitoring. Our goal is to improve asthma monitoring for all children.

Public Health Relevance

Asthma is a progressive inflammatory airways disease that leads to structural airway changes and debilitating symptoms in many affected children. This project will bring a wearable breath sensor to large scale clinical trials for children with asthma within 4 years. At the end of this study, we anticipate our prototype system will have been benchmarked for use specifically in pediatric asthma metabolite monitoring. The final size form and function of the devices will be specifically tailored for use by children on a daily basis.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project--Cooperative Agreements (U01)
Project #
1U01EB022003-01
Application #
9077049
Study Section
Special Emphasis Panel (ZRG1-BST-U (51))
Program Officer
Lash, Tiffani Bailey
Project Start
2015-09-30
Project End
2019-09-29
Budget Start
2015-09-30
Budget End
2019-09-29
Support Year
1
Fiscal Year
2015
Total Cost
$1,454,194
Indirect Cost
$454,194
Name
University of California Davis
Department
Engineering (All Types)
Type
Schools of Engineering
DUNS #
047120084
City
Davis
State
CA
Country
United States
Zip Code
95618
Yamaguchi, Mei S; McCartney, Mitchell M; Linderholm, Angela L et al. (2018) Headspace sorptive extraction-gas chromatography-mass spectrometry method to measure volatile emissions from human airway cell cultures. J Chromatogr B Analyt Technol Biomed Life Sci 1090:36-42
Hagemann, L Tamina; McCartney, Mitchell M; Fung, Alexander G et al. (2018) Portable combination of Fourier transform infrared spectroscopy and differential mobility spectrometry for advanced vapor phase analysis. Analyst 143:5683-5691
Zamuruyev, Konstantin O; Borras, Eva; Pettit, Dayna R et al. (2018) Effect of temperature control on the metabolite content in exhaled breath condensate. Anal Chim Acta 1006:49-60
Zamuruyev, Konstantin O; Schmidt, Alexander J; Borras, Eva et al. (2018) Power-efficient self-cleaning hydrophilic condenser surface for portable exhaled breath condensate (EBC) metabolomic sampling. J Breath Res 12:036020
Zamuruyev, Konstantin O; Zrodnikov, Yuriy; Davis, Cristina E (2017) PHOTOLITHOGRAPHY-FREE LASER-PATTERNED HF ACID-RESISTANT CHROMIUM-POLYIMIDE MASK FOR RAPID FABRICATION OF MICROFLUIDIC SYSTEMS IN GLASS. J Micromech Microeng 27:
Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto et al. (2017) Analytical methodologies for broad metabolite coverage of exhaled breath condensate. J Chromatogr B Analyt Technol Biomed Life Sci 1061-1062:17-25
Peirano, Daniel J; Pasamontes, Alberto; Davis, Cristina E (2016) Supervised Semi-Automated Data Analysis Software for Gas Chromatography / Differential Mobility Spectrometry (GC/DMS) Metabolomics Applications. Int J Ion Mobil Spectrom 19:155-166
Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto et al. (2016) Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler. J Breath Res 11:016001
Zamuruyev, Konstantin O; Aksenov, Alexander A; Baird, Mark et al. (2016) Enhanced non-invasive respiratory sampling from bottlenose dolphins for breath metabolomics measurements. J Breath Res 10:046005