The purpose of these studies is to develop imaging techniques to monitor sub-cellular structures and processes, in vivo. The major approach used was non-linear optical microscopy techniques. We have been systematically developing an in vivo optical microscopy system that is adapted to biological tissues and structures rather than forcing an animal on a conventional microscope stage. The following major findings were made over the last year: 1) Working with industry we have evaluated a commercial condensed version of our epi-Total Emission Detection system for improving the detection efficiency of multiphoton excitation microscopy, in vivo. This initial prototype demonstrated a 2 to 5 fold increase in signal to noise in a variety of tissues including muscle, kidney and fat pads. This is the first step in commercialization of this technology and dissemination of technology generated in LCE to the general scientific community. 2) Furthering our interest in improving the signal to noise of fluorescence microscopy we have developed a new approach in improving the sensitivity of detecting multiple fluorescence probes simultaneously. Previously the overlap of the emission spectra of probes forced the use of restrictive bandwidth filters to resolve the signals from different fluorescence probes. This selective bandwidth significantly reduced the signal to noise of the fluorescence imaging experiment. However, in the case where we can use the prior information of the spectral density of the probes emission and make the assumption that the spatial overlap of the probes is minimal, we demonstrated that by using Independent Component Analysis (ICA) we can determine the spatial distribution of the probes while collecting nearly all of the emitted light. Using this approach, we demonstrated that by simply using a dichroic mirror, causing a minimal loss of light, with a cutoff frequency between the emission energies of the probes as the sole frequency encoding of the data we can properly reconstruct the distribution of the probes within the sample. This approach was shown to dramatically improve the signal to noise of multi-fluorescence probe studies by 2 to 5 fold depending on the spectral overlap of the probes. 3) We have completed our initial study on the distribution of mitochondria within mammalian mixed fiber type skeletal muscle. In these studies we discovered that a large fraction of mitochondrial volume in oxidative fibers is located in regions lateral to a groove surrounding capillaries embedded in the fiber. These studies will be followed up with quantitative 3D electron microscopy studies. 4) A major technological effort this year was the development of CARS microscopy to study the motion of water in intact tissues. We have demonstrated that femto second pulses are much more efficient in generating water CARS signals in biological tissues without compromising the selectivity between proton and deuterium, required for tracer studies. This improvement in signal to noise approached 200 fold in our application. We have demonstrated that water motion can be tracked on the submicron scale with CARS microscopy within intact skeletal muscle using deuterium as a tracer. We are currently characterizing the optical artifacts generated in complex biological tissues to develop appropriate optical or imaging processing techniques to provide compensation.

Project Start
Project End
Budget Start
Budget End
Support Year
7
Fiscal Year
2014
Total Cost
Indirect Cost
Name
U.S. National Heart Lung and Blood Inst
Department
Type
DUNS #
City
State
Country
Zip Code
Glancy, Brian; Hartnell, Lisa M; Combs, Christian A et al. (2017) Power Grid Protection of the Muscle Mitochondrial Reticulum. Cell Rep 19:487-496
Nielles-Vallespin, Sonia; Khalique, Zohya; Ferreira, Pedro F et al. (2017) Assessment of Myocardial Microstructural Dynamics by In Vivo Diffusion Tensor Cardiac Magnetic Resonance. J Am Coll Cardiol 69:661-676
Balaban, Amanda E; Neuman, Keir; Sinnis, Photini et al. (2017) Robust fluorescent labelling of micropipettes for use in fluorescence microscopy: application to the observation of a mosquito borne parasite infection. J Microsc :
Patel, Keval D; Glancy, Brian; Balaban, Robert S (2016) The electrochemical transmission in I-Band segments of the mitochondrial reticulum. Biochim Biophys Acta 1857:1284-1289
Glancy, Brian; Hartnell, Lisa M; Malide, Daniela et al. (2015) Mitochondrial reticulum for cellular energy distribution in muscle. Nature 523:617-20
Dao, Lam; Glancy, Brian; Lucotte, Bertrand et al. (2015) A Model-based approach for microvasculature structure distortion correction in two-photon fluorescence microscopy images. J Microsc 260:180-93
Dao, L; Lucotte, B; Glancy, B et al. (2014) Use of independent component analysis to improve signal-to-noise ratio in multi-probe fluorescence microscopy. J Microsc 256:133-44
Lucotte, B; Balaban, R S (2014) Motion compensation for in vivo subcellular optical microscopy. J Microsc 254:9-12
Glancy, Brian; Hsu, Li-Yueh; Dao, Lam et al. (2014) In vivo microscopy reveals extensive embedding of capillaries within the sarcolemma of skeletal muscle fibers. Microcirculation 21:131-47
Combs, Christian A; Smirnov, Aleksandr; Glancy, Brian et al. (2014) Compact non-contact total emission detection for in vivo multiphoton excitation microscopy. J Microsc 253:83-92

Showing the most recent 10 out of 15 publications