The Computer Core will provide hardware and software resources in support of the Research Projects and Cores of the Program Project. The general focus of the Computer Core is to develop and enhance computer algorithms to facilitate the research on plan optimization, dose computation, treatment implementation, uncertainty analysis and minimizatoin, and to facilitate th eimplementatoin of the research results in close coordination with the Clinical Core. Our major tasks will include the investigation and implementation of automated techniques for image correlation and segmentation, additions and enhancement to the second generation 3DRTP system focusing on the integration of the BEV, Dose Calulation, and Plan Evaluation modules, the development of a unified patient databaseintegrating various sources of information regarding treatment protocol and outcome, and the developmentand implementation of real time quality assurance for dynamic multileaf collimator treatments. The Dosimetry Core is responsible for the safe and accurate delivery of radiatoin dose and is therefore important for many aspectsof this Program Project. The radiation machines under our care for this PPG are the Varian C-Series machines (two 2100Cs and three 600Cs) and the Scanditronix MM50, all equipped with multileaf collimators. Our dose calibration protocol follows the AAPM TG21 recommendations, and patientdosimetryis based on a basic set of measured beam parameters augmented by a pencil beam convolution method forirregular field dosimetry. Of importance to this PPG is the dosimetry of MLC and its application in the dynamic mode (DMLC); the dosimetric effects of the rounded leaf-edge, output for small fields, and leaft transmission need to be considered. In addition, a comprehensive and stringest QA process for DMLC needs to be developed. For these dosimetric measurements and investigations we shall use many approaches, scanning water phantoms, films and TLD dosimetry, and Monte Carlo simulation. Finally, we shall explore the use portal imager as a means of verifying leaf motions and the intensity profiles delivered with DMLC.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Program Projects (P01)
Project #
5P01CA059017-09
Application #
6318298
Study Section
Project Start
2000-07-01
Project End
2001-06-30
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
9
Fiscal Year
2000
Total Cost
$271,628
Indirect Cost
Name
Sloan-Kettering Institute for Cancer Research
Department
Type
DUNS #
064931884
City
New York
State
NY
Country
United States
Zip Code
10065
Bakst, Richard L; Lee, Nancy; Pfister, David G et al. (2011) Hypofractionated dose-painting intensity modulated radiation therapy with chemotherapy for nasopharyngeal carcinoma: a prospective trial. Int J Radiat Oncol Biol Phys 80:148-53
Santoro, Joseph; Kriminski, Sergey; Lovelock, D Michael et al. (2010) Evaluation of respiration-correlated digital tomosynthesis in lung. Med Phys 37:1237-45
Liu, Xiaoxiao; Saboo, Rohit R; Pizer, Stephen M et al. (2009) A SHAPE-NAVIGATED IMAGE DEFORMATION MODEL FOR 4D LUNG RESPIRATORY MOTION ESTIMATION. Proc IEEE Int Symp Biomed Imaging 2009:875-878
Santoro, Joseph P; Yorke, Ellen; Goodman, Karyn A et al. (2009) From phase-based to displacement-based gating: a software tool to facilitate respiration-gated radiation treatment. J Appl Clin Med Phys 10:2982
Lu, Renzhi; Radke, Richard J; Yang, Jie et al. (2008) Reduced-order constrained optimization in IMRT planning. Phys Med Biol 53:6749-66
Sura, Sonal; Gupta, Vishal; Yorke, Ellen et al. (2008) Intensity-modulated radiation therapy (IMRT) for inoperable non-small cell lung cancer: the Memorial Sloan-Kettering Cancer Center (MSKCC) experience. Radiother Oncol 87:17-23
Greco, Carlo; Clifton Ling, C (2008) Broadening the scope of image-guided radiotherapy (IGRT). Acta Oncol 47:1193-200
Kriminski, Sergey A; Lovelock, D Michael; Seshan, Venkatraman E et al. (2008) Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification. Int J Radiat Oncol Biol Phys 71:1572-80
Zhang, Qinghui; Pevsner, Alex; Hertanto, Agung et al. (2007) A patient-specific respiratory model of anatomical motion for radiation treatment planning. Med Phys 34:4772-81
Crouch, Jessica R; Pizer, Stephen M; Chaney, Edward L et al. (2007) Automated finite-element analysis for deformable registration of prostate images. IEEE Trans Med Imaging 26:1379-90

Showing the most recent 10 out of 121 publications