The overall objective of this project is to provide an advanced animal whole body/human brain positron tomograph for the medical science projects. This tomograph will make possible quantitative measurements of cardiovascular physiology in animal models by permitting high count rate dynamic studies with bolus injections of flow and metabolic tracers. It has the following advanced features: Lutetium orthosilicate (LSO) scintillators, which have 6 times greater light output and 8 times faster decay time than bismuth germanate (BGO). Photomultiplier tube readout to provide pulse height information (to reject scattered annihilation photons) and a timing resolution less than 1 ns (to reject random backgrounds). Small (1.5 - 2.5 mm) crystals, read out individually by low-noise silicon photodiodes. Depth of interaction measurement for less than 2 mm spatial resolution over the imaging volume. Small detector dimaeter of 35 cm for low noncollinearity error, high sensitivity, and reduced cost. Full 3D mode over a subject port of 30 cm and an axial field of 15 cm (no inter-plane septa), for high sensitivity and a maximum noise equivalent event rate of greater than 700 k/s at 1 muCi/m1. We expect that U.S. Department of Energy funding will support purchase of the components needed for the 270 detector modules, that CTI PET Systems will provide the labor to assemble and test them, and that this project will provide the following: Construction, testing, and evaluation of pre-production detection modules. Assembling 270 pre-tested detector modules in a gantry at LBL. Evaluating the completed high resolution tomograph. Developing attenuation measurement, background correction, and calibration procedures. This project will advance the technology further by developing time-of-flight capability and installing it in the high resolution LSO tomograph. Our goal is a timing resolution less than 500 ps, which corresponds to less than 7.5 cm. This improves the signal-to-noise ration in the reconstructed 3D images by further reducing the random coincidence background and by localizing the events in 3D to reduce error propagation in the reconstruction process.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Program Projects (P01)
Project #
2P01HL025840-16A1
Application #
6241694
Study Section
Project Start
1997-05-01
Project End
1998-04-30
Budget Start
1996-10-01
Budget End
1997-09-30
Support Year
16
Fiscal Year
1997
Total Cost
Indirect Cost
Name
Lawrence Berkeley National Laboratory
Department
Type
DUNS #
078576738
City
Berkeley
State
CA
Country
United States
Zip Code
94720
VanBrocklin, Henry F; Hanrahan, Stephen M; Enas, Joel D et al. (2007) Mitochondrial avid radioprobes. Preparation and evaluation of 7'(Z)-[125I]iodorotenone and 7'(Z)-[125I]iodorotenol. Nucl Med Biol 34:109-16
Maltz, Jonathan S; Budinger, Thomas F (2005) Evaluation of arterial endothelial function using transit times of artificially induced pulses. Physiol Meas 26:293-307
Marshall, Robert C; Powers-Risius, Patricia; Reutter, Bryan W et al. (2004) Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: comparison to 201Tl. J Nucl Med 45:1950-9
Sitek, Arkadiusz; Gullberg, Grant T; Huesman, Ronald H (2002) Correction for ambiguous solutions in factor analysis using a penalized least squares objective. IEEE Trans Med Imaging 21:216-25
Qi, Jinyi; Huesman, Ronald H (2002) Scatter correction for positron emission mammography. Phys Med Biol 47:2759-71
Klein, Gregory J; Huesman, Ronald H (2002) Four-dimensional processing of deformable cardiac PET data. Med Image Anal 6:29-46
Maltz, Jonathan S (2002) Parsimonious basis selection in exponential spectral analysis. Phys Med Biol 47:2341-65
Reutter, B W; Gullberg, G T; Huesman, R H (2002) Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections. Phys Med Biol 47:2673-83
Huber, J S; Moses, W W; Jones, W F et al. (2002) Effect of 176Lu background on singles transmission for LSO-based PET cameras. Phys Med Biol 47:3535-41
Marshall, R C; Powers-Risius, P; Reutter, B W et al. (2001) Kinetic analysis of 125I-iodorotenone as a deposited myocardial flow tracer: comparison with 99mTc-sestamibi. J Nucl Med 42:272-81

Showing the most recent 10 out of 55 publications