This subproject is one of many research subprojects utilizing theresources provided by a Center grant funded by NIH/NCRR. The subproject andinvestigator (PI) may have received primary funding from another NIH source,and thus could be represented in other CRISP entries. The institution listed isfor the Center, which is not necessarily the institution for the investigator.The goal of the project is to develop and demonstrate two related approaches to molecular analysis and separation that employ flow based analytical instrumentation and magnetic microsphere technology: a magnetic flow spectrometer for separation, and a magnetic flow cytometer for identification. The flow spectrometer system will be unique in enabling highly parallel continuous flow biomolecular separations on a preparative scale, streamlining downstream analysis and revolutionizing our ability to identify potential diagnostic or therapeutic targets. The magnetic flow cytometer will combine a novel magnetic target-molecule tagging concept with fluorescence-based analyte detection. The instrumentation proposed will contribute significantly to a broad range of applications improving human health and quality of life including drug discovery, molecular targeting, DNA analysis, proteomics, and understanding the pathways of cell cycle regulation. We will validate the new instrument by conventional molecular analysis methods and apply it to the study of intracellular vesicle traffic. A product for commercialization is anticipated. Operation of the proposed instrument involves three steps. 1) Magnetically encoded microspheres are prepared by encapsulating strong ferromagnetic material with high remnant magnetization and coercivity, never before used for such applications, in polymer spheres. The distribution of microspheres can be sorted into different bins depending on their intrinsic magnetic moment by flowing through a chamber where a magnetic field gradient induces a force such that they are collected in different bins with narrow distributions of magnetic moment. Microspheres from each bin are chemically bound to target molecules so that each species of magnetic moment is bound to one unique kind of molecule. The collection of microspheres and associated target molecules are then mixed together and incubated with analytes. 2) The incubated collection of microspheres are flowed through a SQUID detector system which identifies the target molecule by measuring the magnetic moment of the microsphere to which it is attached. 3) The analytes will be chemically prepared with molecular groups that fluoresce when illuminated by a laser beam, indicating the target-analyte binding. Combining SQUIDs for target identification with laser diagnostics to assess binding provides an efficient, high throughput multiplexed bioassay method based on traditional flow cytometry.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
2P41RR001315-26
Application #
7598415
Study Section
Special Emphasis Panel (ZRG1-CB-K (40))
Project Start
2007-09-30
Project End
2008-06-30
Budget Start
2007-09-30
Budget End
2008-06-30
Support Year
26
Fiscal Year
2007
Total Cost
$20,964
Indirect Cost
Name
Los Alamos National Lab
Department
Type
DUNS #
175252894
City
Los Alamos
State
NM
Country
United States
Zip Code
87545
Frumkin, Jesse P; Patra, Biranchi N; Sevold, Anthony et al. (2016) The interplay between chromosome stability and cell cycle control explored through gene-gene interaction and computational simulation. Nucleic Acids Res 44:8073-85
Cushing, Kevin W; Piyasena, Menake E; Carroll, Nick J et al. (2013) Elastomeric negative acoustic contrast particles for affinity capture assays. Anal Chem 85:2208-15
Johnson, Leah M; Gao, Lu; Shields IV, C Wyatt et al. (2013) Elastomeric microparticles for acoustic mediated bioseparations. J Nanobiotechnology 11:22
Micheva-Viteva, Sofiya N; Shou, Yulin; Nowak-Lovato, Kristy L et al. (2013) c-KIT signaling is targeted by pathogenic Yersinia to suppress the host immune response. BMC Microbiol 13:249
Ai, Ye; Sanders, Claire K; Marrone, Babetta L (2013) Separation of Escherichia coli bacteria from peripheral blood mononuclear cells using standing surface acoustic waves. Anal Chem 85:9126-34
Sanders, Claire K; Mourant, Judith R (2013) Advantages of full spectrum flow cytometry. J Biomed Opt 18:037004
Piyasena, Menake E; Austin Suthanthiraraj, Pearlson P; Applegate Jr, Robert W et al. (2012) Multinode acoustic focusing for parallel flow cytometry. Anal Chem 84:1831-9
Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A et al. (2012) One-dimensional acoustic standing waves in rectangular channels for flow cytometry. Methods 57:259-71
Vuyisich, Momchilo; Sanders, Claire K; Graves, Steven W (2012) Binding and cell intoxication studies of anthrax lethal toxin. Mol Biol Rep 39:5897-903
Chaudhary, Anu; Ganguly, Kumkum; Cabantous, Stephanie et al. (2012) The Brucella TIR-like protein TcpB interacts with the death domain of MyD88. Biochem Biophys Res Commun 417:299-304

Showing the most recent 10 out of 240 publications