A patent disclosure has been made to the University outlining the potential for MR microscopy as a tool for 3D morphometry of complex, small parts The objects in question are placed in a small chamber which is evacuated to remove air. The chamber is filled with an """"""""imaging solution"""""""". This solution could be Gd/H20, an organic solvent or other source of protons, or hyperpolarized gas. 3D image sets are acquired and the resultant data is inverted ( 2's compliment) to yield an image of the spaces in and surfaces of the object. The specific study will be executed on the plastic closures for sealed bags. These objects have a complex internal structure that is currently a point of interest for colleagues at IIT. Magnevist will be used as the fill solution. Two different types of closures will be imaged, each with subtle internal structural differences.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
2P41RR005959-09
Application #
6282357
Study Section
Project Start
1998-09-30
Project End
1999-08-31
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
9
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Duke University
Department
Type
DUNS #
071723621
City
Durham
State
NC
Country
United States
Zip Code
27705
Tang, Xinyan; Jing, Liufang; Richardson, William J et al. (2016) Identifying molecular phenotype of nucleus pulposus cells in human intervertebral disc with aging and degeneration. J Orthop Res 34:1316-26
Hodgkinson, Conrad P; Bareja, Akshay; Gomez, José A et al. (2016) Emerging Concepts in Paracrine Mechanisms in Regenerative Cardiovascular Medicine and Biology. Circ Res 118:95-107
Schmeckpeper, Jeffrey; Verma, Amanda; Yin, Lucy et al. (2015) Inhibition of Wnt6 by Sfrp2 regulates adult cardiac progenitor cell differentiation by differential modulation of Wnt pathways. J Mol Cell Cardiol 85:215-25
Roos, Justus E; McAdams, Holman P; Kaushik, S Sivaram et al. (2015) Hyperpolarized Gas MR Imaging: Technique and Applications. Magn Reson Imaging Clin N Am 23:217-29
He, Mu; Robertson, Scott H; Kaushik, S Sivaram et al. (2015) Dose and pulse sequence considerations for hyperpolarized (129)Xe ventilation MRI. Magn Reson Imaging 33:877-85
Huang, Lingling; Walter, Vonn; Hayes, D Neil et al. (2014) Hedgehog-GLI signaling inhibition suppresses tumor growth in squamous lung cancer. Clin Cancer Res 20:1566-75
Huang, Jing; Guo, Jian; Beigi, Farideh et al. (2014) HASF is a stem cell paracrine factor that activates PKC epsilon mediated cytoprotection. J Mol Cell Cardiol 66:157-64
Yuan, Ying; Gilmore, John H; Geng, Xiujuan et al. (2014) FMEM: functional mixed effects modeling for the analysis of longitudinal white matter Tract data. Neuroimage 84:753-64
He, Mu; Kaushik, S Sivaram; Robertson, Scott H et al. (2014) Extending semiautomatic ventilation defect analysis for hyperpolarized (129)Xe ventilation MRI. Acad Radiol 21:1530-41
van Rhoon, Gerard C; Samaras, Theodoros; Yarmolenko, Pavel S et al. (2013) CEM43°C thermal dose thresholds: a potential guide for magnetic resonance radiofrequency exposure levels? Eur Radiol 23:2215-27

Showing the most recent 10 out of 239 publications