Diffusion-weighted imaging (DWI) is a sensitive and specific indicator of stroke, but is hindered in the clinical setting by its sensitivity to patient motion. This has precipitated the move towards single shot Echo Planar techniques (EPI) and high speed gradient hardware. The purpose of this work was to develop a multishot diffusion-weighted Echo Planar sequence in order to reduce the susceptibility sensitivity of EPI. Since the mutishot approach reintroduces the sensitivity to patient motion, we incorporated a navigator echo into the WPI sequence to compensate for motion effects. Methods and Results The modified EPI pulse sequence consists of a pair of diffusion-sensitizing gradients about a 1800 refocusing pulse. An EPI readout of 8-32 echoes follows the second diffusion sensitizing gradient. The sequence is repeated as many times as needed to make up the full image data set. We performed all imaging with resolution: 128x128, FOV: 24 cm, b values: 0-509 s/mm2, and peripheral gating. IEPI was performed at two gradient configurations with differing parameters and compared to single shot EPI performed with the high speed gradients. A navigator echo was acquired immediately before the readout in the IEPI sequence. The motion induced phase changes from each shot were estimated from the phase of the navigator echo after lDFT. This phase was used to correct all echoes in the image data from that shot. The navigator motion-correction scheme dramatically improved the image quality in all multishot images. Images acquired with navigated IEPI had less susceptibility distortion than the single shot images around the sinuses and minimal motion artifacts. Discussion Multishot Echo Planar Imaging, in combination with cardiac gating and phase correction with navigator echoes, is a robust and efficient means of acquiring diffusion-weighted data on either conventional or high speed gradient hardware.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-02
Application #
5225773
Study Section
Project Start
Project End
Budget Start
Budget End
Support Year
2
Fiscal Year
1996
Total Cost
Indirect Cost
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Suh, Ga-Young; Choi, Gilwoo; Herfkens, Robert J et al. (2016) Three-Dimensional Modeling Analysis of Visceral Arteries and Kidneys during Respiration. Ann Vasc Surg 34:250-60
Ong, Frank; Lustig, Michael (2016) Beyond Low Rank + Sparse: Multi-scale Low Rank Matrix Decomposition. IEEE J Sel Top Signal Process 10:672-687

Showing the most recent 10 out of 446 publications