Introduction: The ability to localize and differentiate between hypoxic and well-oxygenated tumors in vivo may aid in the staging of treatment and affect the choice of therapeutic agent. This potentially can be achieved through the use of magnetic resonance spectroscopy (MRS) to measure the relative concentrations of two molecules 1)lactate - a marker for non-oxidative glycolysis, and 2) choline - when enhanced, a marker for active tumor. To assess metastatic neck nodes resulting from primary occurances of squamous cell carcinoma, we have implemented a new J-difference editing scheme using band selective inversion with gradient dephasing (BASING) which was developed for water suppression and lactate rephasing. BASING applied to lactate editing is unique in that the four benefits are provided: 1) singlet suppression with resilience to B1-scaling errors, 2) easy incorporation into localization sequences such as point resolved spectroscopy (PRESS) 3) arbitrary echo times for TE >= 1/J, and 4) RF pulses with steep transition bands that are required to maintain visibility of the choline resonance. Methods: Data were collected from 8 patients and volunteers with the following scan parameters: TR = 2s, TE = 144 ms, number of acquisitions = 256. A 4-element head, neck and cervical phased-array coil (MRI Devices Corp., Waukesha, WI.) operating in receive-only mode was used to maximize coverage and the SNR. To achieve robust separation of lactate from the singlets, a novel phase regularization algorithm, which compensated for phase and frequency variations between successive excitations, was developed. Results: Data from the neck muscle of a normal volunteer showed that a lipid suppression factor of over 1000 was achievable with use of the phase regularization algorithm. The spectra from the neck tumor nodes demonstrated variable amounts of choline and lactate detected. However, the two spectra with the most lactate and choline had median pO2 values of approximately 0.7 mm Hg which is highly suggestive of hypoxia Conclusions: We have demonstrated the use of a new MRS technique capable of detecting both choline and lactate resonances in vivo in head and neck tumors. This has not previously been accomplished and may offer a noninvasive means of differentiating between necrosis, hypoxic and well-oxygenated tumors.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-04
Application #
6282979
Study Section
Project Start
1998-01-01
Project End
1998-12-31
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
4
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Stanford University
Department
Type
DUNS #
800771545
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications