Purpose: Detailed examination of cartilage with short T2 relaxation times near the cartilage/bone interface may provide accurate measurements of cartilage thickness and information about collagen fiber organization. This information could be important in assessment of normal cartilage structure, injury and chondrocyte transplants. We have developed a method for high resolution short echo time spectroscopic imaging of cartilage. Materials and Methods: The short echo time spectroscopic imaging sequence uses either a half-pulse (TE 0.2 ms) or conventional excitation (TE 1.6 ms). Excitation is followed immediately by projection reconstruction readout gradients. Minimum FOV is 6 cm, with an in-plane resolution of 117 micrometers. Slice thickness is 2-3 mm, and scan time is from 4.5 to 9 minutes. Spectral resolution is 1.0 ppm, and spectral bandwidth is 6.7 ppm. Reconstruction of the 33 megabyte data set takes 4 minutes on a Sun Ultrasparc. All imaging was done on a 1.5T GE Signa with Echospeed gradients. Results: Ten normal volunteers and four patients with cartilage transplants have been studied. Normal cartilage shows increasing line width and decreasing peak area when moving from the articular surface towards the bone. Spectroscopic imaging resolves chemical shift artifact, and the short echo time allows evaluation of the cartilage in the calcified zone near the bony cortex. Conclusion: High resolution spectroscopic imaging of articular cartilage can be performed on a whole-body scanner. This technique may yield new information about the organization and type of collagen fibers present. It may be possible to follow the development and integration of chondrocyte transplants, and distinguish fibrocartilage from hyaline cartilage at the transplant site.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-04
Application #
6282951
Study Section
Project Start
1998-01-01
Project End
1998-12-31
Budget Start
1997-10-01
Budget End
1998-09-30
Support Year
4
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Stanford University
Department
Type
DUNS #
800771545
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications