This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. Introduction: Conventional visual field mapping contrasts stimuli at a series of visual field locations. Visual field map estimates identify the most effective stimulus position at each cortical location. Conventional methods (a) do not include a blank period, so that it is impossible to know whether all stimuli cause some response, and (b) summarize responses by a single variable that indicates only the most effective stimulus location. We introduce a new stimulus protocol and time-series modeling that provide additional information about cortical visual field sensitivity. Methods and Discussion: Conventional expanding ring and rotating wedge contrast stimuli were modified by inserting a time period with zero contrast (mean-luminance). The new paradigm allows us to compare contrast responses at multiple locations with a zero contrast stimulus and estimate a better spatial model of the local cortical visual field responsivity from the response time course. Besides conventional Fourier analysis, the response components were estimated using a general linear model. Cortex within V1-V3 is predominantly sensitive to stimulus location. Lateral and ventral occipital cortex respond to stimuli from a much larger part of the visual field, but is also sensitive to stimulus location. The transition between V1 and LO maps is particularly distinctive, allowing segregation of the confluent foveal regions that are otherwise hard to discern.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR009784-12
Application #
7358829
Study Section
Special Emphasis Panel (ZRG1-SBIB-F (40))
Project Start
2006-06-01
Project End
2007-05-31
Budget Start
2006-06-01
Budget End
2007-05-31
Support Year
12
Fiscal Year
2006
Total Cost
$3,118
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Maclaren, Julian; Aksoy, Murat; Ooi, Melvyn B et al. (2018) Prospective motion correction using coil-mounted cameras: Cross-calibration considerations. Magn Reson Med 79:1911-1921
Guo, Jia; Holdsworth, Samantha J; Fan, Audrey P et al. (2018) Comparing accuracy and reproducibility of sequential and Hadamard-encoded multidelay pseudocontinuous arterial spin labeling for measuring cerebral blood flow and arterial transit time in healthy subjects: A simulation and in vivo study. J Magn Reson Imaging 47:1119-1132
Tamir, Jonathan I; Uecker, Martin; Chen, Weitian et al. (2017) T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging. Magn Reson Med 77:180-195
Lai, Lillian M; Cheng, Joseph Y; Alley, Marcus T et al. (2017) Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia. J Magn Reson Imaging 45:1407-1418
Taviani, Valentina; Alley, Marcus T; Banerjee, Suchandrima et al. (2017) High-resolution diffusion-weighted imaging of the breast with multiband 2D radiofrequency pulses and a generalized parallel imaging reconstruction. Magn Reson Med 77:209-220
Uecker, Martin; Lustig, Michael (2017) Estimating absolute-phase maps using ESPIRiT and virtual conjugate coils. Magn Reson Med 77:1201-1207
Kogan, Feliks; Hargreaves, Brian A; Gold, Garry E (2017) Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho. Magn Reson Med 77:1134-1141
Aksoy, Murat; Maclaren, Julian; Bammer, Roland (2017) Prospective motion correction for 3D pseudo-continuous arterial spin labeling using an external optical tracking system. Magn Reson Imaging 39:44-52
Bian, W; Tranvinh, E; Tourdias, T et al. (2016) In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol 37:1808-1815
Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying et al. (2016) Trade-off between angular and spatial resolutions in in vivo fiber tractography. Neuroimage 129:117-132

Showing the most recent 10 out of 446 publications