This subproject is one of many research subprojects utilizing theresources provided by a Center grant funded by NIH/NCRR. The subproject andinvestigator (PI) may have received primary funding from another NIH source,and thus could be represented in other CRISP entries. The institution listed isfor the Center, which is not necessarily the institution for the investigator.Vibrational Cooling (VC) MALDI-FTMS generates ions by desorbing/ionizing analytes under 1-10 mbar of collision gas. This method allows for detection of labile species with FTMS resolution and accuracy, making this instrument highly applicable for proteomic experiments, particularly for the analysis of labile post-translational modifications (PTMs). However, once the ions are generated, it is necessary to perform MS/MS experiments on them. This project concerns investigation of use of multiple collisional activation events as a tandem mass spectrometry method which provides nearly full sequence coverage for these peptides. VC MALDI FTMS has previously been described [1]. In the described experiments, multishot accumulation was used to acquire high abundance of ions in the hexapole. Subsequently ions were transferred to the cell, where precursor ions were isolated by SWIFT. These ions were then subjected to a series of on- and off- resonant excitation events similar to MECA technique [2] and SORI [Jacobsen]. Synthetic peptides were used to probe the fragmentation of unmodified and post-translationally modified peptides with varying lability. Experiments using a series of SORI- and MECA- type collisional activation events were performed on peptides formed by VC MALDI. As expected, SORI-CAD of these peptides generated a few specific cleavages. However, use of multiple SORI and MECA events for activation yielded high quality CAD spectra of these peptides, generating b/y type cleavage at almost every peptide bond. Furthermore, these CAD spectra when generated on the VC-MALDI-FTMS instrument preserved the information regarding the position of labile post-translational modifications such as phosphorylation and o-glycosylation. The same peptides, when analyzed with ESI-FTMS using the same multi-CAD approach, tended to preferentially lose the labile PTM and lose the positional information. When applying multi-CAD to peptides with labile side chain modifications, such as O-glycosylation on Ser and/or Thr residues, and single and multiple phosphorylation on Ser and Thr, information-rich spectra are generated. Most of the fragment ions in the product ion spectra still carry the labile side chain modification(s) providing nearly complete sequence information and unambiguous localization of the sites of modifications. Ongoing work is investigating the application of this technique to sulfated peptides, glycolipids and carbohydrates which are normally extremely difficult to analyze by CAD-based MS/MS methods.1. O'Connor PB, Mirgorodskaya E, Costello CE JASMS 2002, 13, 402-4072. Lee SA, Jiao CQ, Huang YQ, Freiser BS RCM 1993, 7(9), 819-821

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
2P41RR010888-11
Application #
7602006
Study Section
Special Emphasis Panel (ZRG1-BCMB-H (40))
Project Start
2007-08-03
Project End
2008-05-31
Budget Start
2007-08-03
Budget End
2008-05-31
Support Year
11
Fiscal Year
2007
Total Cost
$22,624
Indirect Cost
Name
Boston University
Department
Biochemistry
Type
Schools of Medicine
DUNS #
604483045
City
Boston
State
MA
Country
United States
Zip Code
02118
Lu, Yanyan; Jiang, Yan; Prokaeva, Tatiana et al. (2017) Oxidative Post-Translational Modifications of an Amyloidogenic Immunoglobulin Light Chain Protein. Int J Mass Spectrom 416:71-79
Sethi, Manveen K; Zaia, Joseph (2017) Extracellular matrix proteomics in schizophrenia and Alzheimer's disease. Anal Bioanal Chem 409:379-394
Hu, Han; Khatri, Kshitij; Zaia, Joseph (2017) Algorithms and design strategies towards automated glycoproteomics analysis. Mass Spectrom Rev 36:475-498
Ji, Yuhuan; Bachschmid, Markus M; Costello, Catherine E et al. (2016) S- to N-Palmitoyl Transfer During Proteomic Sample Preparation. J Am Soc Mass Spectrom 27:677-85
Hu, Han; Khatri, Kshitij; Klein, Joshua et al. (2016) A review of methods for interpretation of glycopeptide tandem mass spectral data. Glycoconj J 33:285-96
Pu, Yi; Ridgeway, Mark E; Glaskin, Rebecca S et al. (2016) Separation and Identification of Isomeric Glycans by Selected Accumulation-Trapped Ion Mobility Spectrometry-Electron Activated Dissociation Tandem Mass Spectrometry. Anal Chem 88:3440-3
Wang, Yun Hwa Walter; Meyer, Rosana D; Bondzie, Philip A et al. (2016) IGPR-1 Is Required for Endothelial Cell-Cell Adhesion and Barrier Function. J Mol Biol 428:5019-5033
Srinivasan, Srimathi; Chitalia, Vipul; Meyer, Rosana D et al. (2015) Hypoxia-induced expression of phosducin-like 3 regulates expression of VEGFR-2 and promotes angiogenesis. Angiogenesis 18:449-62
Yu, Xiang; Sargaeva, Nadezda P; Thompson, Christopher J et al. (2015) In-Source Decay Characterization of Isoaspartate and ?-Peptides. Int J Mass Spectrom 390:101-109
Steinhorn, Benjamin S; Loscalzo, Joseph; Michel, Thomas (2015) Nitroglycerin and Nitric Oxide--A Rondo of Themes in Cardiovascular Therapeutics. N Engl J Med 373:277-80

Showing the most recent 10 out of 253 publications