This subproject is one of many research subprojects utilizing the resources provided by a Center grant funded by NIH/NCRR. The subproject and investigator (PI) may have received primary funding from another NIH source, and thus could be represented in other CRISP entries. The institution listed is for the Center, which is not necessarily the institution for the investigator. Recent work (Mathur et al., 2008) on a new, higher sensitivity preamplifier design for Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) revealed a number of artifact peaks (spectral features) which do not contain useful chemical information. In order to determine the cause of these artifacts and eliminate them, these severely distorted spectra were compared with similarly distorted signal models (Mathur et al., 2009). C60 was chosen as the compound of interest, whose mass spectra were obtained using the custom built 7T MALDI FT-ICR mass spectrometer. Simulated spectra were generated using a MATLAB script. Three undamped sinusoidal functions were used to model the first three isotopes of C60. It was found that imbalance in the gain or bias of the amplifier could lead to overloading of the analogue to digital converter (ADC) which resulted in appearance of harmonics in the mass spectra. This observation was confirmed by simulation, where clipping of one side of the digital transient led to appearance of multiple harmonics peaks in the simulated spectra. Fold-over peaks due to under-sampling (aliasing) were also apparent for higher order harmonics peaks. It was further shown that severe overloading of the ADC (even when the amplifier is perfectly balanced with no DC offsets) could also cause distortion in the isotopic distribution of ions, which would make the automatic interpretation of the mass spectra difficult. Finally, radio-frequency interference (RFI) noise riding on the ICR signal causing imbalance and/or overloading of the ADC may also induce intermodulations between isotopic peaks and the RFI noise, leading to undesirable artifacts. Thus, the source of several common signal processing artifacts was thereby determined and correlated to RFI noise and saturation of the amplifier and/or the digitizer. Under such conditions, the fast Fourier transform (FFT) generates spectral artifact peaks corresponding to harmonics and mixing frequencies of the real signal peaks and RFI frequencies. While this study was done using the FT-ICR MS data, it is important to stress that these artifacts are inherent to the digitization and FFT process and thus are relevant to any FT-based MS instrument, including the orbitrap and FT ion trap.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR010888-13
Application #
7955973
Study Section
Special Emphasis Panel (ZRG1-BCMB-H (40))
Project Start
2009-06-01
Project End
2010-05-31
Budget Start
2009-06-01
Budget End
2010-05-31
Support Year
13
Fiscal Year
2009
Total Cost
$4,673
Indirect Cost
Name
Boston University
Department
Biochemistry
Type
Schools of Medicine
DUNS #
604483045
City
Boston
State
MA
Country
United States
Zip Code
02118
Lu, Yanyan; Jiang, Yan; Prokaeva, Tatiana et al. (2017) Oxidative Post-Translational Modifications of an Amyloidogenic Immunoglobulin Light Chain Protein. Int J Mass Spectrom 416:71-79
Sethi, Manveen K; Zaia, Joseph (2017) Extracellular matrix proteomics in schizophrenia and Alzheimer's disease. Anal Bioanal Chem 409:379-394
Hu, Han; Khatri, Kshitij; Zaia, Joseph (2017) Algorithms and design strategies towards automated glycoproteomics analysis. Mass Spectrom Rev 36:475-498
Ji, Yuhuan; Bachschmid, Markus M; Costello, Catherine E et al. (2016) S- to N-Palmitoyl Transfer During Proteomic Sample Preparation. J Am Soc Mass Spectrom 27:677-85
Hu, Han; Khatri, Kshitij; Klein, Joshua et al. (2016) A review of methods for interpretation of glycopeptide tandem mass spectral data. Glycoconj J 33:285-96
Pu, Yi; Ridgeway, Mark E; Glaskin, Rebecca S et al. (2016) Separation and Identification of Isomeric Glycans by Selected Accumulation-Trapped Ion Mobility Spectrometry-Electron Activated Dissociation Tandem Mass Spectrometry. Anal Chem 88:3440-3
Wang, Yun Hwa Walter; Meyer, Rosana D; Bondzie, Philip A et al. (2016) IGPR-1 Is Required for Endothelial Cell-Cell Adhesion and Barrier Function. J Mol Biol 428:5019-5033
Steinhorn, Benjamin S; Loscalzo, Joseph; Michel, Thomas (2015) Nitroglycerin and Nitric Oxide--A Rondo of Themes in Cardiovascular Therapeutics. N Engl J Med 373:277-80
Walsh, Erica M; Niu, MengMeng; Bergholz, Johann et al. (2015) Nutlin-3 down-regulates retinoblastoma protein expression and inhibits muscle cell differentiation. Biochem Biophys Res Commun 461:293-9
Théberge, Roger; Dikler, Sergei; Heckendorf, Christian et al. (2015) MALDI-ISD Mass Spectrometry Analysis of Hemoglobin Variants: a Top-Down Approach to the Characterization of Hemoglobinopathies. J Am Soc Mass Spectrom 26:1299-310

Showing the most recent 10 out of 253 publications