Conventional piezoelectric materials such as PZT-5H for transducer may not be suitable for VHF transducer and array fabrication. Moreover, better piezoelectric materials with higher coupling coefficient and variable dielectric constant allowing for wider bandwidth and more flexible transducer design are needed for the improvement of conventional linear array performance as well as the development of multidimensional arrays. In this project, fine grain PZT which has smaller grain size and single crystal relaxor materials such as PZN-PT which has a much higher coupling coefficient than PZT-5H will be prepared and improved for VHF linear array fabrication. In addition 1-3 fiber composites prepared via a sol-gel process will be developed for VHF single element transducers. The potential of these materials has been demonstrated by the better performance in bandwidth and sensitivity of ultrasonic transducers prepared from these materials in comparison to those prepared from PZT-5H under similar conditions.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR011795-04
Application #
6348234
Study Section
Project Start
2000-09-01
Project End
2001-08-31
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
4
Fiscal Year
2000
Total Cost
$138,993
Indirect Cost
Name
Pennsylvania State University
Department
Type
DUNS #
City
University Park
State
PA
Country
United States
Zip Code
16802
Reddy, Anilkumar K; Hartley, Craig J; Pham, Thuy T et al. (2014) Young little mice express a premature cardiovascular aging phenotype. J Gerontol A Biol Sci Med Sci 69:152-9
Crossland, Randy F; Durgan, David J; Lloyd, Eric E et al. (2013) A new rodent model for obstructive sleep apnea: effects on ATP-mediated dilations in cerebral arteries. Am J Physiol Regul Integr Comp Physiol 305:R334-42
Gurha, Priyatansh; Wang, Tiannan; Larimore, Ashley H et al. (2013) microRNA-22 promotes heart failure through coordinate suppression of PPAR/ERR-nuclear hormone receptor transcription. PLoS One 8:e75882
Nagamani, Sandesh C S; Campeau, Philippe M; Shchelochkov, Oleg A et al. (2012) Nitric-oxide supplementation for treatment of long-term complications in argininosuccinic aciduria. Am J Hum Genet 90:836-46
Lee, Hyeong Jae; Zhang, Shujun (2012) Design of low-loss 1-3 piezoelectric composites for high-power transducer applications. IEEE Trans Ultrason Ferroelectr Freq Control 59:1969-75
Lloyd, Eric E; Crossland, Randy F; Phillips, Sharon C et al. (2011) Disruption of K(2P)6.1 produces vascular dysfunction and hypertension in mice. Hypertension 58:672-8
Hartley, Craig J; Reddy, Anilkumar K; Madala, Sridhar et al. (2011) Doppler velocity measurements from large and small arteries of mice. Am J Physiol Heart Circ Physiol 301:H269-78
Chintalgattu, Vishnu; Ai, Di; Langley, Robert R et al. (2010) Cardiomyocyte PDGFR-beta signaling is an essential component of the mouse cardiac response to load-induced stress. J Clin Invest 120:472-84
Song, Liang; Maslov, Konstantin; Shung, K Kirk et al. (2010) Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo. J Biomed Opt 15:021303
Zhang, Shujun; Sherlock, Nevin P; Meyer, Richard J et al. (2009) Crystallographic dependence of loss in domain engineered relaxor-PT single crystals. Appl Phys Lett 94:162906

Showing the most recent 10 out of 24 publications