The high frequency cardiac Doppler system developed at Baylor has been used for many years for studying small animals and patients. However, the performance of the transducers is relatively poor and can be further improved by including driver and receiver characteristics into the design process. The KLM model was employed to model the RF components of the Baylor Doppler system as an ABCD parameter network, include source and receiver impedances, cable lengths and transducer active and passive components. Two active materials were studied as transducer components, a PZT 5A (Motorola 3195) and a modified lead titanate (Edo EC-97). Active areas and cable lengths were varied, and modifications were made to the RF electronics to provide an optimum operation point for the Doppler transducers. Optimization of the two active materials lead to area versus sensitivity curves with an overall optimum achieved in the lead titanate; however because of the low dielectric constant, the optimal area was too large to be practical for cardiac Doppler measurements on mice. The optimum design using the Baylor configured system was found to be a 1.6mm diameter PZT5A transducer. A 330pF capacitor was inserted in series with the transducer on the RF board replacing an existing jumper, tuning the source and receive impedances to nearly real values and the designs were re-optimized. Using these modified source and receiver impedances, the overall optimum transducer design which remained practical for fine Doppler measurements was determined to be a 2.6mm diameter PZT5A transducer with a simple epoxy matching layer and a light, but structurally rigid backing of conductive micro-balloons. Future work on this project include a similar procedure with the Baylor 20 MHz system as well as application of Resource PZFlex code to analyze lens effects on transducer behavior and beam profiles.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR011795-04
Application #
6348245
Study Section
Project Start
2000-09-01
Project End
2001-08-31
Budget Start
1998-10-01
Budget End
1999-09-30
Support Year
4
Fiscal Year
2000
Total Cost
$9,236
Indirect Cost
Name
Pennsylvania State University
Department
Type
DUNS #
City
University Park
State
PA
Country
United States
Zip Code
16802
Reddy, Anilkumar K; Hartley, Craig J; Pham, Thuy T et al. (2014) Young little mice express a premature cardiovascular aging phenotype. J Gerontol A Biol Sci Med Sci 69:152-9
Gurha, Priyatansh; Wang, Tiannan; Larimore, Ashley H et al. (2013) microRNA-22 promotes heart failure through coordinate suppression of PPAR/ERR-nuclear hormone receptor transcription. PLoS One 8:e75882
Crossland, Randy F; Durgan, David J; Lloyd, Eric E et al. (2013) A new rodent model for obstructive sleep apnea: effects on ATP-mediated dilations in cerebral arteries. Am J Physiol Regul Integr Comp Physiol 305:R334-42
Nagamani, Sandesh C S; Campeau, Philippe M; Shchelochkov, Oleg A et al. (2012) Nitric-oxide supplementation for treatment of long-term complications in argininosuccinic aciduria. Am J Hum Genet 90:836-46
Lee, Hyeong Jae; Zhang, Shujun (2012) Design of low-loss 1-3 piezoelectric composites for high-power transducer applications. IEEE Trans Ultrason Ferroelectr Freq Control 59:1969-75
Lloyd, Eric E; Crossland, Randy F; Phillips, Sharon C et al. (2011) Disruption of K(2P)6.1 produces vascular dysfunction and hypertension in mice. Hypertension 58:672-8
Hartley, Craig J; Reddy, Anilkumar K; Madala, Sridhar et al. (2011) Doppler velocity measurements from large and small arteries of mice. Am J Physiol Heart Circ Physiol 301:H269-78
Chintalgattu, Vishnu; Ai, Di; Langley, Robert R et al. (2010) Cardiomyocyte PDGFR-beta signaling is an essential component of the mouse cardiac response to load-induced stress. J Clin Invest 120:472-84
Song, Liang; Maslov, Konstantin; Shung, K Kirk et al. (2010) Ultrasound-array-based real-time photoacoustic microscopy of human pulsatile dynamics in vivo. J Biomed Opt 15:021303
Zhang, Shujun; Sherlock, Nevin P; Meyer, Richard J et al. (2009) Crystallographic dependence of loss in domain engineered relaxor-PT single crystals. Appl Phys Lett 94:162906

Showing the most recent 10 out of 24 publications