This subproject is one of many research subprojects utilizing theresources provided by a Center grant funded by NIH/NCRR. The subproject andinvestigator (PI) may have received primary funding from another NIH source,and thus could be represented in other CRISP entries. The institution listed isfor the Center, which is not necessarily the institution for the investigator.Verification and tuning procedures related to bridge setup for ESR spectroscopy are, in general, greatly facilitated by swept-frequency measurement of transmitted/reflected power. Swept-frequency evaluation methods are especially useful in the millimeter-wave regime, and even more so when quasioptical techniques are employed, mainly due to the numerous interacting adjustments and enhanced quasioptical bridge susceptibility to extra-path reflections. As useful as swept measurement capability is, off-the-shelf test and measurement instrumentation providing phase-locked swept-frequency capability at even the lower millimeter-wave regime (i.e., below 100 GHz) is inordinately expensive and, above that frequency range, appears to be available only on an even more expensive custom-built basis. For this reason, ACERT had not previously invested in millimeter-wave swept-measurement capability for its 170 and 250GHz c.w. spectrometer bridges.Last year, ACERT acquired significantly improved millimeter-wave sources of center frequencies at 170 and 240 GHz for its high-field c.w. quasioptical ESR spectrometers. These units generate approximately 12dB more output power than the previous c.w. sources and provide phase-locked operation over a relatively broad frequency range of fc 5 GHz. In view of the significantly higher output power available from these sources, an extensive program of bridge and resonator design upgrades was undertaken for optimized bridge operation in inductive-reflection mode. During the course of this development work, it became evident not only that swept-frequency measurement capability would be indispensable, but also, conveniently, that these extended-range c.w. sources might be pressed into service for such incidental use. Our work to date in this area has resulted in an interim 170GHz swept-frequency system which has proven extremely useful in the setup and fine-tuning of the H.F. reflection bridge. We have found that, although the swept output power is not actively leveled, the source multiplier stage bias levels may easily be tuned to provide better than 1.2 dB flatness at fc 1.0GHz and approximately 3dB over the entire source tracking range from 165 to 175GHz. This performance level is more than sufficient for general bridge and resonator tuning procedures. Given the encouraging results thus far, we plan to continue this project over the coming year with similar investigation of the new 240GHz tracking c.w. source for swept measurements. During the coming year, we plan to continue with the design, construction, installation and programming of a simplified operator interface for switching between normal c.w. operation and the swept-frequency diagnostic modes.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biotechnology Resource Grants (P41)
Project #
5P41RR016292-08
Application #
7723924
Study Section
Special Emphasis Panel (ZRG1-BCMB-K (40))
Project Start
2008-09-01
Project End
2009-08-31
Budget Start
2008-09-01
Budget End
2009-08-31
Support Year
8
Fiscal Year
2008
Total Cost
$2,690
Indirect Cost
Name
Cornell University
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
872612445
City
Ithaca
State
NY
Country
United States
Zip Code
14850
Jain, Rinku; Vanamee, Eva S; Dzikovski, Boris G et al. (2014) An iron-sulfur cluster in the polymerase domain of yeast DNA polymerase ?. J Mol Biol 426:301-8
Pratt, Ashley J; Shin, David S; Merz, Gregory E et al. (2014) Aggregation propensities of superoxide dismutase G93 hotspot mutants mirror ALS clinical phenotypes. Proc Natl Acad Sci U S A 111:E4568-76
Georgieva, Elka R; Borbat, Peter P; Ginter, Christopher et al. (2013) Conformational ensemble of the sodium-coupled aspartate transporter. Nat Struct Mol Biol 20:215-21
Airola, Michael V; Sukomon, Nattakan; Samanta, Dipanjan et al. (2013) HAMP domain conformers that propagate opposite signals in bacterial chemoreceptors. PLoS Biol 11:e1001479
Airola, Michael V; Huh, Doowon; Sukomon, Nattakan et al. (2013) Architecture of the soluble receptor Aer2 indicates an in-line mechanism for PAS and HAMP domain signaling. J Mol Biol 425:886-901
Sun, Yan; Zhang, Ziwei; Grigoryants, Vladimir M et al. (2012) The internal dynamics of mini c TAR DNA probed by electron paramagnetic resonance of nitroxide spin-labels at the lower stem, the loop, and the bulge. Biochemistry 51:8530-41
Smith, Andrew K; Freed, Jack H (2012) Dynamics and ordering of lipid spin-labels along the coexistence curve of two membrane phases: an ESR study. Chem Phys Lipids 165:348-61
Yu, Renyuan Pony; Darmon, Jonathan M; Hoyt, Jordan M et al. (2012) High-Activity Iron Catalysts for the Hydrogenation of Hindered, Unfunctionalized Alkenes. ACS Catal 2:1760-1764
Gaffney, Betty J; Bradshaw, Miles D; Frausto, Stephen D et al. (2012) Locating a lipid at the portal to the lipoxygenase active site. Biophys J 103:2134-44
Dzikovski, Boris; Tipikin, Dmitriy; Freed, Jack (2012) Conformational distributions and hydrogen bonding in gel and frozen lipid bilayers: a high frequency spin-label ESR study. J Phys Chem B 116:6694-706

Showing the most recent 10 out of 72 publications