There is an increasing recognition that, in the long term, total joint replacement (TJR) may be associated with adverse local and remote tissue responses that are mediated by the degradation products of prosthetic materials. There has been particular interest in the metallic degradation products of THR because of the known toxicities of the metallic elements that comprise the implant alloys. In this long term study, we have been investigating metal release, transport, storage and excretion in patients with total hip and knee replacements. In the current grant period, we have demonstrated that (1) elevations in serum titanium and chromium can be detected in individuals with well functioning total hip and knee replacements; (2) the highest chromium and cobalt levels have been observed in patients with metal-on-metal bearings; (3) passive dissolution from extensively porous coated cobalt- base alloy femoral stems is not a dominant model of metal release; rather, fretting corrosion of femoral components at modular junctions is more closely associated with elevations in serum chromium; (4) cobalt- and titanium-alloy particulate degradation products from TJR commonly disseminate to paraaortic lymph nodes, liver and spleen, particularly in individuals who have had a failed TJR; and (5) there are indications that individuals with elevated serum metal content may have associated liver cell injury. We propose to expand on these studies to (1) quantify metal release in the prospective study group which will be 7 to 12 years postoperative, an interval in which complications related to the implant are more prevalent; (2) prospectively follow patients up to 8 years after revision surgery who have demonstrated significant elevations in serum metal content to determine if serum metal transport diminishes with time; (3) expand our autopsy retrieval program to characterize not only tissue metal levels and systemic distribution of particulate wear debris but also the tissue and cellular localization of these degradation products; and (4) conduct bioavailability and bioreactivity studies of circulating metal-protein complexes which result from corrosion and wear of joint replacement components. This is one of four grants in an Orthopaedic Biomaterials Investigator- Initiated Interactive Research Project Grant entitled """"""""Safety and Efficacy of Permanent Skeletal Replacement Implants"""""""". The studies proposed here address safety issues and are deemed critical in order to understand the prospective risks to patients undergoing total joint arthroplasty.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
3R01AR039310-12S1
Application #
6550587
Study Section
Orthopedics and Musculoskeletal Study Section (ORTH)
Program Officer
Panagis, James S
Project Start
1989-05-01
Project End
2003-12-31
Budget Start
2002-01-01
Budget End
2002-12-31
Support Year
12
Fiscal Year
2002
Total Cost
$8,061
Indirect Cost
Name
Rush University Medical Center
Department
Surgery
Type
Schools of Medicine
DUNS #
City
Chicago
State
IL
Country
United States
Zip Code
60612
Lachiewicz, Paul F; Watters, Tyler Steven; Jacobs, Joshua J (2016) Metal Hypersensitivity and Total Knee Arthroplasty. J Am Acad Orthop Surg 24:106-12
Hallab, Nadim J; Caicedo, Marco; McAllister, Kyron et al. (2013) Asymptomatic prospective and retrospective cohorts with metal-on-metal hip arthroplasty indicate acquired lymphocyte reactivity varies with metal ion levels on a group basis. J Orthop Res 31:173-82
Hsu, Andrew R; Levine, Brett R; Skipor, Anastasia K et al. (2013) Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty. Am J Orthop (Belle Mead NJ) 42:E84-7
Levine, Brett R; Hsu, Andrew R; Skipor, Anastasia K et al. (2013) Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*. J Bone Joint Surg Am 95:512-8
Cooper, H John; Della Valle, Craig J; Berger, Richard A et al. (2012) Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am 94:1655-61
Mathew, Mathew T; Jacobs, Joshua J; Wimmer, Markus A (2012) Wear-corrosion synergism in a CoCrMo hip bearing alloy is influenced by proteins. Clin Orthop Relat Res 470:3109-17
Urban, Robert M; Hall, Deborah J; Della Valle, Craig et al. (2012) Successful long-term fixation and progression of osteolysis associated with first-generation cementless acetabular components retrieved post mortem. J Bone Joint Surg Am 94:1877-85
Laurent, Michel P; Pourzal, Robin; Fischer, Alfons et al. (2011) In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report. J Bone Joint Surg Am 93:e27
Guyer, Richard D; Shellock, Jessica; MacLennan, Benjamin et al. (2011) Early failure of metal-on-metal artificial disc prostheses associated with lymphocytic reaction: diagnosis and treatment experience in four cases. Spine (Phila Pa 1976) 36:E492-7
Wright, Geoffrey; Sporer, Scott; Urban, Robert et al. (2010) Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am 92:1518-21

Showing the most recent 10 out of 54 publications