Surgical treatment of anterior cruciate ligament (ACL) deficiency is common, but unfortunately, no single procedure has been able to restore knee kinematics to pre-injury levels. In fact, using the International Knee Documentation committee (IKDC) guidelines, 38% of the patients were reported to have abnormal, or severely abnormal knees. Therefore, advancements in surgical ACL reconstruction, and post-operative rehabilitation to improve the outcome, would require a better understanding of the forces in the intact ACL. The broad aim of this project is to examine the in situ force and its distribution within the ACL and ACL replacement grafts under external loads, with and without muscle stabilization. It is the applicants' belief, that the intact ACL is the true """"""""gold standard"""""""" for ACL reconstruction. Using cadaveric knees, data on both the in situ forces and knee kinematics will be obtained and used to evaluate ACL reconstruction, particularly on important variables such as graft type, number of bundles, and notchplasty. The investigators will use a newly developed robotic/universal force-moment sensor (UFS) testing system to determine the in situ forces and knee kinematics. Complex human knee motion in 6 degrees-of-freedom (DOF) will be recorded and then reproduced using a robotic manipulator. In situ forces in the intact ACL and its replacement grafts will be obtained from force data measured by the UFS. Further, this technology will yield data on the changes in knee kinematics secondary to ACL reconstruction. The same specimen can be utilized for a series of tests, allowing the intact knee joint to serve as its own control (thus minimizing interspecimen variations). It is suggested that information obtained from the proposed studies will be useful for the clinical management of ACL deficiency. It is the applicants' goal to provide data for surgeons to help them select appropriate ACL replacement grafts and reconstruction procedures, and to improve rehabilitation protocols. In the long-term, they believe that the robotic/UFS test system can be used to reproduce the knee kinematics data obtained from in vivo activities on cadaveric knees. Thus, the in situ forces and force distribution in the ACL and replacement grafts during the activities of daily living and sports could be indirectly determined.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
Research Project (R01)
Project #
3R01AR039683-10S1
Application #
6294416
Study Section
Special Emphasis Panel (ZRG4 (05))
Program Officer
Panagis, James S
Project Start
1990-12-01
Project End
2002-06-30
Budget Start
2000-04-01
Budget End
2002-06-30
Support Year
10
Fiscal Year
2000
Total Cost
$31,049
Indirect Cost
Name
University of Pittsburgh
Department
Orthopedics
Type
Schools of Medicine
DUNS #
053785812
City
Pittsburgh
State
PA
Country
United States
Zip Code
15213
Baka, Nora; Kaptein, Bart L; Giphart, J Erik et al. (2014) Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy. J Biomech 47:122-9
Torry, Michael R; Shelburne, Kevin B; Myers, Casey et al. (2013) High knee valgus in female subjects does not yield higher knee translations during drop landings: a biplane fluoroscopic study. J Orthop Res 31:257-67
Baka, N; de Bruijne, M; van Walsum, T et al. (2012) Statistical shape model-based femur kinematics from biplane fluoroscopy. IEEE Trans Med Imaging 31:1573-83
Myers, Casey A; Torry, Michael R; Shelburne, Kevin B et al. (2012) In vivo tibiofemoral kinematics during 4 functional tasks of increasing demand using biplane fluoroscopy. Am J Sports Med 40:170-8
Torry, Michael R; Shelburne, Kevin B; Peterson, Daniel S et al. (2011) Knee kinematic profiles during drop landings: a biplane fluoroscopy study. Med Sci Sports Exerc 43:533-41
Torry, Michael R; Myers, Casey; Shelburne, Kevin B et al. (2011) Relationship of knee shear force and extensor moment on knee translations in females performing drop landings: a biplane fluoroscopy study. Clin Biomech (Bristol, Avon) 26:1019-24
Myers, Casey A; Torry, Michael R; Peterson, Daniel S et al. (2011) Measurements of tibiofemoral kinematics during soft and stiff drop landings using biplane fluoroscopy. Am J Sports Med 39:1714-22
Abramowitch, Steven D; Zhang, Xiaoyan; Curran, Molly et al. (2010) A comparison of the quasi-static mechanical and non-linear viscoelastic properties of the human semitendinosus and gracilis tendons. Clin Biomech (Bristol, Avon) 25:325-31
Zamarra, Giovanni; Fisher, Matthew B; Woo, Savio L-Y et al. (2010) Biomechanical evaluation of using one hamstrings tendon for ACL reconstruction: a human cadaveric study. Knee Surg Sports Traumatol Arthrosc 18:11-9
Darcy, Shon P; Gil, Jorge E; Woo, Savio L-Y et al. (2009) The importance of position and path repeatability on force at the knee during six-DOF joint motion. Med Eng Phys 31:553-7

Showing the most recent 10 out of 83 publications