Quantitative single photon emission compute tomography (SPECT) has been limited mainly by the inadequate number of detected photons in the projections, attenuation within the body, the inclusion of scattered photons in the projections, and variations in collimator response with distance. The long term objectives of this project are: 1) to increase the number of detected photons by using new acquisition geometries, and 2) to develop and evaluate a unified reconstruction methodology for SPECT using a statistical Bayesian formulation. Cone beam collimation (CB) can result in a three-fold increase in the number of detected photons, compared with a parallel beam (PB) collimator having similar resolution characteristics. Bayesian image processing (BIP) can integrally include the a priori source distribution entropy information, the Poisson nature of the measured projection data, as well as other a priori information concerning the shift-variant point spread function. Filtered backprojection (FBP) is widely used since it offers the practical advantage of fast computational speed; however, BIP offers the potential for a more accurate reconstruction. Other statistical estimators, such as maximum likelihood (ML) and maximum entropy (MAXENT) are directly derivable from the Bayesian formulation. This project will evaluate cone beam SPECT using FBP and BIP approaches. A validated Monte Carlo model of the acquisition geometry will be used to determine the system response matrix. Receiver operator characteristic (ROC) curves will be used to evaluate lesion detectability for CB, fan beam (FB), and PB SPECT. The convergence characteristics of BIP will be quantitatively compared with ML and MAXENT, as a function of iteration number. Simulated and experimentally acquired projections of phantoms will be used to evaluate BIP for quantification of activity, activity ratios, resolution, and noise cone beam SPECT. Patient scans acquired with CB, FB, and parallel hole collimation will be compared. Early results indicate that cone beam collimation offers the potential for improved SPECT imaging. The application of a unified BIP algorithm that simultaneously compensates for attenuation, scatter, and collimator variations should offer further improvements in the accuracy of the reconstruction, and provide the basis for fundamental advances in SPECT quantification.

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
5R01CA033541-10
Application #
3171394
Study Section
Diagnostic Radiology Study Section (RNM)
Project Start
1983-03-01
Project End
1994-02-28
Budget Start
1992-03-01
Budget End
1993-02-28
Support Year
10
Fiscal Year
1992
Total Cost
Indirect Cost
Name
Duke University
Department
Type
Schools of Medicine
DUNS #
071723621
City
Durham
State
NC
Country
United States
Zip Code
27705
Miller, Keith L; Shafman, Timothy D; Anscher, Mitchell S et al. (2005) Bronchial stenosis: an underreported complication of high-dose external beam radiotherapy for lung cancer? Int J Radiat Oncol Biol Phys 61:64-9
Tornai, Martin P; Bowsher, James E; Jaszczak, Ronald J et al. (2003) Mammotomography with pinhole incomplete circular orbit SPECT. J Nucl Med 44:583-93
Metzler, S D; Bowsher, J E; Greer, K L et al. (2002) Analytic determination of the pinhole collimator's point-spread function and RMS resolution with penetration. IEEE Trans Med Imaging 21:878-87
Woel, Roxanne T; Munley, Michael T; Hollis, Donna et al. (2002) The time course of radiation therapy-induced reductions in regional perfusion: a prospective study with >5 years of follow-up. Int J Radiat Oncol Biol Phys 52:58-67
Bowsher, J E; Tornai, M P; Peter, J et al. (2002) Modeling the axial extension of a transmission line source within iterative reconstruction via multiple transmission sources. IEEE Trans Med Imaging 21:200-15
Krol, A; Bowsher, J E; Manglos, S H et al. (2001) An EM algorithm for estimating SPECT emission and transmission parameters from emissions data only. IEEE Trans Med Imaging 20:218-32
Fan, M; Marks, L B; Lind, P et al. (2001) Relating radiation-induced regional lung injury to changes in pulmonary function tests. Int J Radiat Oncol Biol Phys 51:311-7
Fan, M; Marks, L B; Hollis, D et al. (2001) Can we predict radiation-induced changes in pulmonary function based on the sum of predicted regional dysfunction? J Clin Oncol 19:543-50
Metzler, S D; Bowsher, J E; Smith, M F et al. (2001) Analytic determination of pinhole collimator sensitivity with penetration. IEEE Trans Med Imaging 20:730-41
Marks, L B; Fan, M; Clough, R et al. (2000) Radiation-induced pulmonary injury: symptomatic versus subclinical endpoints. Int J Radiat Biol 76:469-75

Showing the most recent 10 out of 84 publications