The investigators propose to apply magnetic resonance imaging (MRI) techniques developed in the previous funding cycle of this grant to MR angiography imaging. The specific hypothesis to be tested is that high resolution arterial phase angiograms devoid of motion artifact can be reliably acquired in major vascular regions (renal, carotid, aorta, pulmonary) using intravenous contrast administration. Despite growing interest, 3-D contrast enhanced MR angiography is limited by major physical phenomena including: Uncertainties of timing, contamination by unwanted venous signal, limited spatial resolution, and, in the thoracic and abdominal regions, motion artifact. These all affect the overall reliability. The investigators propose to combine two methods to deal with these problems: (I) an elliptical centric view order, and (ii) real-time MR fluoroscopy. With the end product an operator will monitor the targeted vascular area with real-time MR Fluoroscopy and upon detection of contrast material immediately trigger a 3-D scan with a view order optimum for high resolution arterial phase imaging. Specific projects to be studied are: 1. Elliptical Centric 3DFT MR Acquisition. The fundamental ability of the elliptical view order to distinguish arterial and venous phases will be assessed theoretically and experimentally using hypothetical and measured contrast enhancement curves. TR times will be reduced to provide improved resolution; 2. MR Fluoroscopic Triggering. Imaging sequences and hardware will be developed for real-time monitoring of contrast material proximal to the targeted vasculature for the high resolution 3DFT sequence. Means will be developed for instantaneous initiation of the 3-D scan. Partial k-space updating with nonuniform sampling will be implemented for improved temporal resolution. Means will be studied to facilitate positioning of the fluoroscopic plane of section; and 3. System integration and adaptation to targeted vascular areas. The basic technique will be adapted to specific anatomic areas. Physical parameters to be accounted for include fast contrast passage (especially in pulmonary imaging), fine resolution in all three dimensions (carotid, renal), extended field of view (pulmonary, aorta) and multiple temporal frames (renal).

Agency
National Institute of Health (NIH)
Institute
National Cancer Institute (NCI)
Type
Research Project (R01)
Project #
2R01CA037993-13
Application #
2470447
Study Section
Special Emphasis Panel (ZRG7-DMG (01))
Program Officer
Torres-Anjel, Manuel J
Project Start
1984-08-01
Project End
1999-11-30
Budget Start
1997-12-15
Budget End
1998-11-30
Support Year
13
Fiscal Year
1998
Total Cost
Indirect Cost
Name
Mayo Clinic, Rochester
Department
Type
DUNS #
City
Rochester
State
MN
Country
United States
Zip Code
55905
Campeau, N G; Johnson, C D; Felmlee, J P et al. (1995) MR imaging of the abdomen with a phased-array multicoil: prospective clinical evaluation. Radiology 195:769-76
Slavin, G S; Butts, K; Rydberg, J N et al. (1995) Dual-echo interleaved echo-planar imaging of the brain. Magn Reson Med 33:264-70
Jack Jr, C R; Thompson, R M; Butts, R K et al. (1994) Sensory motor cortex: correlation of presurgical mapping with functional MR imaging and invasive cortical mapping. Radiology 190:85-92
Bampton, A E; Riederer, S J; Korin, H W (1992) Centric phase-encoding order in three-dimensional MP-RAGE sequences: application to abdominal imaging. J Magn Reson Imaging 2:327-34
Bampton, A E; Riederer, S J (1992) Improved efficiency in 2DFT magnetization-prepared rapid gradient echo imaging: application to abdominal imaging. Magn Reson Med 25:195-203
Brown, D G; Lee, J N; Blinder, R A et al. (1990) CNR enhancement in the presence of multiple interfering processes using linear filters. Magn Reson Med 14:79-96
Holsinger, A E; Wright, R C; Riederer, S J et al. (1990) Real-time interactive magnetic resonance imaging. Magn Reson Med 14:547-53
Wang, H Z; Riederer, S J (1990) A spoiling sequence for suppression of residual transverse magnetization. Magn Reson Med 15:175-91
Holsinger, A E; Riederer, S J (1990) The importance of phase-encoding order in ultra-short TR snapshot MR imaging. Magn Reson Med 16:481-8
Riederer, S J; Tasciyan, T; Farzaneh, F et al. (1988) MR fluoroscopy: technical feasibility. Magn Reson Med 8:1-15

Showing the most recent 10 out of 24 publications