This proposal seeks to continue the development of a reliable implantable sensor for glucose. Such a device could eventually be used as part of an artificial pancreas consisting of a sensor, a microprocessor-driven data acquisition and control system and a pump to be used for insulin infusion. More immediately, however, the goal is to develop a monitoring system which will continuously record blood glucose levels. Continuous monitoring is expected to be useful for two purposes: 1. To provide an alarm system which will warn the diabetic of the impending onset of a hypoglycemic episode and 2. To provide a glycemia-time profile which should be useful to the clinician in devising an insulin administration regimen. The needle-type subcutaneously implanted sensor for the above purpose has been extensively tested in rats and dogs and its reliability has been established. It remains therefore to test the sensor in humans to determine: 1. Does the sensor function reliably in humans? and 2. Do the data produced yield clinically useful results? To answer these questions a series of clinical studies are proposed. The first series involves testing sensor and control unit performance on healthy volunteers. This will be accomplished at Hotel- Dieu in Paris. Starting in the second year (Year 8) clinical trials will be carried out simultaneously in Paris and KU Medical Center. Studies will be made on Type I insulin dependent diabetics to provide additional support for the reliability and ease of use of the system and to study particularly nocturnal hypoglycemia. Long term (1 week intervals) implantation will also be investigated as well as the evaluation of effectiveness of diabetes management using the monitoring unit. There remain some important fundamental and practical questions relating to sensor and control unit function which must be resolved. The sensor will be modified to render it unresponsive to acetaminophen. Several aspects of in-vivo performance will also be studied. For the monitoring unit it will be necessary to improve signal processing algorithms and to develop user-friendly data analysis techniques.

Agency
National Institute of Health (NIH)
Institute
National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK)
Type
Research Project (R01)
Project #
5R01DK030718-08
Application #
2138487
Study Section
Metabolism Study Section (MET)
Project Start
1987-09-01
Project End
1995-12-31
Budget Start
1994-01-01
Budget End
1994-12-31
Support Year
8
Fiscal Year
1994
Total Cost
Indirect Cost
Name
University of Kansas Lawrence
Department
Chemistry
Type
Schools of Arts and Sciences
DUNS #
072933393
City
Lawrence
State
KS
Country
United States
Zip Code
66045
Choleau, C; Klein, J C; Reach, G et al. (2002) Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method. Biosens Bioelectron 17:647-54
Choleau, C; Klein, J C; Reach, G et al. (2002) Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current. Biosens Bioelectron 17:641-6
Aussedat, B; Dupire-Angel, M; Gifford, R et al. (2000) Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring. Am J Physiol Endocrinol Metab 278:E716-28
Yu, P; Wilson, G S (2000) An independently addressable microbiosensor array: what are the limits of sensing element density? Faraday Discuss :305-17; discussion 335-51
Labat-Allietta, N; Thevenot, D R (1998) Influence of calcium on glucose biosensor response and on hydrogen peroxide detection. Biosens Bioelectron 13:19-29
Hu, Y; Wilson, G S (1997) A temporary local energy pool coupled to neuronal activity: fluctuations of extracellular lactate levels in rat brain monitored with rapid-response enzyme-based sensor. J Neurochem 69:1484-90
Hu, Y; Wilson, G S (1997) Rapid changes in local extracellular rat brain glucose observed with an in vivo glucose sensor. J Neurochem 68:1745-52
Aussedat, B; Thome-Duret, V; Reach, G et al. (1997) A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm. Biosens Bioelectron 12:1061-71
Thome-Duret, V; Gangnerau, M N; Zhang, Y et al. (1996) Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue. Diabetes Metab 22:174-8
Jung, S K; Wilson, G S (1996) Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors. Anal Chem 68:591-6

Showing the most recent 10 out of 33 publications