Cardiac arrhythmias are a major clinical health problem. We have developed a significant and unique solution. During the current award period, we have designed, constructed and successfully tested a novel prototype system which integrates, in real-time, all image and associated physiological variables, device signals and computer generated data derived there from required for accurate navigation and precise targeting in catheter- based ablation of cardiac arrhythmias. The system renders obsolete or unnecessary current approaches to such treatment, including open chest surgery, pacemakers, medications that don't work, and present ablation systems. Our system design is advanced, open and flexible, permitting ready integration of new imaging modalities, interventional devices and physiologic signals as they become available. This system has achieved, for the first time, real-time performance in fusing dynamic cardiac anatomy with physiologic signals. Based on this promising, but preliminary progress, we now can specify and complete the requirements for seamless clinical implementation and application. These requirements include enhancement, optimization and addition of novel algorithms and technology. We will achieve real-time segmentation of pre- and intra- operative image data, including dyna-CT and 3D ultrasound. The segmented multimodality data will be fused in real-time in the procedure room. Using tissue characterization and catheter tracking, we will develop and validate an innovative approach to physiologic visualization of intra-operative ablation (""""""""burn"""""""") sites. This capability will provide accurate visualization of the burn targets on anatomy to guide and verify the desired ablation pattern. These high-performance segmentation, fusion and visualization capabilities will be the basis for the final real-time platform for cardiac ablation guidance, which will be fully validated in detailed animal experiments. The system will be demonstrated efficacious both in the standard clinical set-up using catheter tracking and x-ray fluoroscopy (and/or pre-operative CT) and in an advanced set-up using a robotic manipulator for precise and stable catheter control. The system will be fully documented to facilitate ready reproduction. This project is poised to deliver a new generation of technology for effective treatment of cardiac arrhythmias that will result in significant clinical benefits, including dramatically improved outcomes with reduced morbidity, mortality, procedure time, x-ray exposure and cost.

Public Health Relevance

Cardiac arrhythmias are a major public health problem with limited effective treatment options. The project will deliver a new generation of technology based upon multi-dimensional image fusion and guidance that will provide effective treatment of cardiac arrhythmias, resulting in significant clinical benefits which include dramatically improved outcomes (cases) while reducing morbidity, mortality, procedure time, x-ray exposure and cost.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Research Project (R01)
Project #
5R01EB002834-09
Application #
8248089
Study Section
Biomedical Imaging Technology Study Section (BMIT)
Program Officer
Krosnick, Steven
Project Start
2003-09-20
Project End
2014-06-30
Budget Start
2012-04-01
Budget End
2014-06-30
Support Year
9
Fiscal Year
2012
Total Cost
$475,230
Indirect Cost
$170,795
Name
Mayo Clinic, Rochester
Department
Type
DUNS #
006471700
City
Rochester
State
MN
Country
United States
Zip Code
55905
Linte, Cristian A; Camp, Jon J; Rettmann, Maryam E et al. (2018) Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring. J Med Imaging (Bellingham) 5:021218
Peters, Terry M; Linte, Cristian A (2016) Image-guided interventions and computer-integrated therapy: Quo vadis? Med Image Anal 33:56-63
Rettmann, M E; Holmes 3rd, D R; Johnson, S B et al. (2015) Analysis of Left Atrial Respiratory and Cardiac Motion for Cardiac Ablation Therapy. Proc SPIE Int Soc Opt Eng 9415:
Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E et al. (2015) The effect of elastic modulus on ablation catheter contact area. Proc SPIE Int Soc Opt Eng 9415:
Sun, Deyu; Rettmann, Maryam E; Packer, Douglas et al. (2015) Simulated evaluation of an intraoperative surface modeling method for catheter ablation by a real phantom simulation experiment. Proc SPIE Int Soc Opt Eng 9415:
Rettmann, Maryam E; Holmes 3rd, David R; Breen, Jerome F et al. (2015) Measurements of the left atrium and pulmonary veins for analysis of reverse structural remodeling following cardiac ablation therapy. Comput Methods Programs Biomed 118:198-206
Rettmann, M E; Holmes 3rd, D R; Linte, C A et al. (2014) Toward Standardized Mapping for Left Atrial Analysis and Cardiac Ablation Guidance. Proc SPIE Int Soc Opt Eng 9036:
Sun, Deyu; Rettmann, Maryam E; Holmes Iii, David R et al. (2014) Anatomic surface reconstruction from sampled point cloud data and prior models. Stud Health Technol Inform 196:387-93
Rettmann, Maryam E; Holmes 3rd, David R; Kwartowitz, David M et al. (2014) Quantitative modeling of the accuracy in registering preoperative patient-specific anatomic models into left atrial cardiac ablation procedures. Med Phys 41:021909
Linte, Cristian A; Camp, Jon J; Rettmann, Maryam E et al. (2013) Image-based Modeling and Characterization of RF Ablation Lesions in Cardiac Arrhythmia Therapy. Proc SPIE Int Soc Opt Eng 8671:

Showing the most recent 10 out of 20 publications