This proposal is in response to the NCRR """"""""High End Instrumentation Grant Program S10"""""""" (RFA: PAR-11- 228) to expand our investment in improved instrumentation for the advancement of biomedical research in Stanford's interdisciplinary programs including the Richard M. Lucas Center for Imaging (Lucas Center), Center for Biomedical Imaging at Stanford (CBIS), and the Molecular Imaging Program at Stanford (MIPS). Translational biomedical research is of the utmost importance today and, with the rapid advances in molecular medicine and stem cells, imaging plays a vital role. We are requesting funds to purchase a General Electric Healthcare Spinlab"""""""" dynamic nuclear polarizer needed to extend our current 13C magnetic resonance spectroscopic imaging (MRSI) efforts. Specifically, we have built a highly successful experimental hyperpolarized 13C metabolic imaging program, but, so far, only technical research and small animal studies have been conducted due to the limitations of our pre-clinical polarizer. The proposed new polarizer will allow us to build upon this program with the additional capability of performing large animal and human studies, a critical step forward in the development of this promising technology. Providing more than a 10,000 fold increase in signal-to-noise ratio (SNR) as compared to thermally polarized 13C nuclei, hyperpolarized MRS forms an important bridge between MRI and molecular imaging, and the new polarizer will enable sophisticated metabolic imaging studies of cancer, heart disease, and other pathologies while ensuring the continued development of advanced hyperpolarized 13C MRS methods for years to come. The Spinlab polarizer will be located within the Lucas Center, which operates as a university Service Center and as an NCRR-funded National Research Resource (Center for Advanced MR Technology at Stanford), supplying state-of-the-art MR instrumentation and services to the campus and broader research community. A primary mission of the Stanford Department of Radiology is the translation of promising new imaging modalities from the laboratory setting to the clinic. The acquisition of this new DNP polarizer is directly aligned with this goal and has great potential to provide new insights into health and disease, ultimately improving patient care.

Agency
National Institute of Health (NIH)
Institute
Office of The Director, National Institutes of Health (OD)
Type
Biomedical Research Support Shared Instrumentation Grants (S10)
Project #
1S10OD012283-01
Application #
8333704
Study Section
Special Emphasis Panel (ZRG1-SBIB-X (30))
Program Officer
Levy, Abraham
Project Start
2013-05-01
Project End
2014-04-30
Budget Start
2013-05-01
Budget End
2014-04-30
Support Year
1
Fiscal Year
2013
Total Cost
$2,000,000
Indirect Cost
Name
Stanford University
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
009214214
City
Stanford
State
CA
Country
United States
Zip Code
94305
Wibowo, Arif; Park, Jae Mo; Liu, Shie-Chau et al. (2017) Real-Time in Vivo Detection of H2O2 Using Hyperpolarized 13C-Thiourea. ACS Chem Biol 12:1737-1742
Corbin, Zachary; Spielman, Daniel; Recht, Lawrence (2017) A Metabolic Therapy for Malignant Glioma Requires a Clinical Measure. Curr Oncol Rep 19:84
Park, Jae Mo; Khemtong, Chalermchai; Liu, Shie-Chau et al. (2017) In vivo assessment of intracellular redox state in rat liver using hyperpolarized [1-13 C]Alanine. Magn Reson Med 77:1741-1748
Datta, Keshav; Spielman, Daniel M (2017) Doublet asymmetry for estimating polarization in hyperpolarized 13 C-pyruvate studies. NMR Biomed 30:
Park, Jae Mo; Wu, Marvin; Datta, Keshav et al. (2017) Hyperpolarized Sodium [1-13C]-Glycerate as a Probe for Assessing Glycolysis In Vivo. J Am Chem Soc 139:6629-6634
Tee, Sui Seng; Park, Jae Mo; Hurd, Ralph E et al. (2017) PKM2 activation sensitizes cancer cells to growth inhibition by 2-deoxy-D-glucose. Oncotarget 8:90959-90968
Park, Jae Mo; Josan, Sonal; Jang, Taichang et al. (2016) Volumetric spiral chemical shift imaging of hyperpolarized [2-(13) c]pyruvate in a rat c6 glioma model. Magn Reson Med 75:973-84
Park, Jae Mo; Spielman, Daniel M; Josan, Sonal et al. (2016) Hyperpolarized (13)C-lactate to (13)C-bicarbonate ratio as a biomarker for monitoring the acute response of anti-vascular endothelial growth factor (anti-VEGF) treatment. NMR Biomed 29:650-9
Park, Jae Mo; Josan, Sonal; Mayer, Dirk et al. (2015) Hyperpolarized 13C NMR observation of lactate kinetics in skeletal muscle. J Exp Biol 218:3308-18