We would like to purchase a microcomputed tomography (micro-CT) system for the Hospital for Special Surgery to acquire high resolution morphometry and density information from bone samples. Several NIH- sponsored investigators at our institution and at other academic institutions in New York City are studying bone development, repair, and adaptation. For these investigators, understanding skeletal integrity (the biological, chemical, and mechanical influences that make bone such a distinctive tissue) is a fundamental part of their research. Taking advantage of advances in molecular biology and genetics, these researchers are integrating biology and engineering into in vivo experiments using small anhnal models to examine the relation between composition, structure, and function that allows the skeleton to fulfill its unique role. The purchase of a micro-CT system will provide crucial detailed structural information on the small bones from these animals that will complement compositional measurements (from infrared imaging) and functional data (from mechanical testing and finite element analyses). For example, the ability to resolve morphomet:ric details at nearly the same resolution (<20 microns) with micro-CT as we are able to resolve mineral and matrix compositional properties (< 10 microns) with infrared imaging creates unique capabilities to examine composition-structure-function relations in trabecular bone at ultrastructural levels of tissue organization. The value of micro-CT has been demonstrated in preliminary studies in which time has been borrowed on a system in The Netherlands. However, the large number of investigators who could benefit and the large number of new research questions that will arise by having a system at our institution far outweighs our ability to acquire sufficient time on other systems. The grant for the micro-CT system will be administered within the Core Center for Skeletal Integrity, a new NIH-sponsored center (p30 AR46121) organized under an Administrative Core with research cores in Analytical Microscopy, Infrared Imaging, and Mechanical Testing. The micro-CT system will be housed within the Analytical Microscopy core, and policies and procedures for its use, maintenance, and oversight will follow from those already established for the Core Center. This administrative procedure will insure optimal use, long-term operation, and maintenance of the equipment as part of the institution's commitment to the Core Center.

Agency
National Institute of Health (NIH)
Institute
National Center for Research Resources (NCRR)
Type
Biomedical Research Support Shared Instrumentation Grants (S10)
Project #
1S10RR014801-01
Application #
6053115
Study Section
Special Emphasis Panel (ZRG1-SSS-7 (80))
Program Officer
Tingle, Marjorie
Project Start
2000-04-01
Project End
2001-03-31
Budget Start
2000-04-01
Budget End
2001-03-31
Support Year
1
Fiscal Year
2000
Total Cost
$178,000
Indirect Cost
Name
Hospital for Special Surgery
Department
Type
DUNS #
622146454
City
New York
State
NY
Country
United States
Zip Code
10021
Tommasini, Steven M; Wearne, Susan L; Hof, Patrick R et al. (2008) Percolation theory relates corticocancellous architecture to mechanical function in vertebrae of inbred mouse strains. Bone 42:743-50
Fritton, J Christopher; Myers, Elizabeth R; Wright, Timothy M et al. (2008) Bone mass is preserved and cancellous architecture altered due to cyclic loading of the mouse tibia after orchidectomy. J Bone Miner Res 23:663-71
Fritton, J C; Myers, E R; Wright, T M et al. (2005) Loading induces site-specific increases in mineral content assessed by microcomputed tomography of the mouse tibia. Bone 36:1030-8
Tommasini, Steven M; Morgan, Timothy G; van der Meulen, Marjolein Ch et al. (2005) Genetic variation in structure-function relationships for the inbred mouse lumbar vertebral body. J Bone Miner Res 20:817-27